Promotic
WikipediaLinkedInYoutubeTwitterFacebook

Preconfiguration "Single line graph defined by y and x values"

Creates the PmgCanvas object configured as - Single line graph defined by y and x values.
 
This preconfiguration can be activated when creating a new Pmg object and is included in the group: " / Chart, functions".
 
This object contains embedded PmgCanvas object named Dynamic. The item has the variable X_Data and Y_Data of the String type containing values separated by semicolon. It is possible to connect it to the measured value of the same data structure by data binding. The variables of the parent object are accessible in the onDraw event by using the pEvent.GetParentVar().
 
In the PmgCanvas object, there are variables minX, maxX, minY, maxY, spaceX and spaceY. These variables define the scale range in both x and y axes and also the offset of axes from left and bottom edge of the Pmg object.
 
Additional configuration variables are located at the beginning of context itself, or at the beginning of designer's methods. The following items can be set: Values of variables titleX and titleY allow user defined labeling of axes x and y.
- colorScale color of ticks and scale descriptions
- nMajY number of main ticks on y axis
- nMinY number of minor ticks (between two main ticks) on y axis
- nDescPer specifies the quantity of displayed descriptors of main ticks (0 = no, 1 = every main, 2 = every second main)
- nMajX number of main ticks on x axis
- nMinX number of minor ticks (between two main ticks) on x axis
- colorArea background color of the graph rendering area
- colorGrid grid color
- nGridPer specifies quantity of displayed horizontal/vertical grid lines (0 = no, 1 = every main, 2 = every second main)
- nTextSize scale description text size

For embedded Pmg object

- ctx.lineWidth value represents the thickness of the rendered graph line
- ctx.strokeStyle value represents the color of rendered graph line
These configurators can be set before the preconfiguration is created:
Object nameName (identifier) of the Pmg object. It is used to obtain the Pmg object by the PmgObject.Items method.

This configurator sets the initial value of the property Name.

This is a system name, so it must contain only alphanumeric and must not contain any diacritics, empty string, spaces and the first character must not be a number.

Range from minimum (x)Low limit of the x axis
Range to maximum (x)High limit of the x axis
Range from minimum (y)Low limit of the y axis
Range to maximum (y)High limit of the y axis
Graph line colorGraph line color
Axis label XAxis user defined label X
Axis label YAxis user defined label Y
Values (x)Base values on the x axis separated by semicolon
Values (y)Base values on the y axis separated by semicolon
Data emulation in control variable bindingEmulated data will be generated in the control variable

History:
Pm8.03.24: Single line graph defined by y and x values
PROMOTIC 9.0.7 SCADA system documentation - MICROSYS, spol. s r.o.