Preconfiguration "PmModbusMr - Papouch up to 32 temperature and humidity sensors multi (radio) (Modbus TCP/IP) - Communication set with data and panel"

Communication by the Modbus TCP/IP protocol with meters via TME multi or radio.
See also Communication with meters by the Papouch company (Czechia).

The valid TCP-IP address must be set for the device according to the corresponding network environment. The configuration is described in the documentation supplied by the manufacturer.

This preconfiguration can be activated when creating a new object (e.g. by "New object ..." in the local object menu or by pressing the Insert key after selecting the object) and is included in the group: "/ Communication / Protocols and other communications / Modbus".
This preconfiguration can be created in the object: PmaFolder or PmaRoot.

- The preconfiguration creates an object of the PmaFolder type containing PmaComm object with PmaCommGroup subobject and following objects: PmaPanel, PmaData, PmaTrendGroup.
- The preconfiguration is created including the panel (object of the PmaPanel type) is functional also as Web panel.
- The panel is used for communication testing and it is not essential for the communication functionality.


In the PmaComm object named "Comm" the communication parameters are set (Network address, ...).
The PmaCommGroup object named "data" includes a "Parameters" tab where Special Parameters are defined (see PmModbusMr - Driver for communication by the Modbus Master protocol). On the "Data" tab, the items are imported by data extension of items defined in the PmaData object (see ExtComm). Each Data corresponds to the selected device type by its structure and name.

These configurators can be set before the preconfiguration is created:
The name of created objectName of the object created in the Pma objects tree. The maximum name length is 30 characters. This is a system name, so it must contain only alphanumeric and must not contain any diacritics (i.e. national dependent characters), empty string, spaces and the first character must not be a number.
Default: "CommTME"
Network addressNetwork address of the remote device (e.g. of the PLC device), to which the communication will be connected.
The address can be entered as:
- IPv4 full address (e.g. "192.168.0.15")
- IPv4 address of this computer (i.e. "127.0.0.1")
- IPv4 computer name (e.g. "server11")
- IPv4 name of this computer (i.e. "localhost")
- IPv6 full address (e.g. "2a02:c38:8136:800a:37a:ab66:6fc9:accd")
- IPv6 address of this computer (i.e. "::1")

Macro expression can be used for input (it is evaluated after the application is launched).
After the preconfiguration is created, the "PmaComm > Setting the parameters of the Ethernet-client > Network address" configurator will be set to this value.
Communication refresh rate [ms]The period in milliseconds to be used for reading the current data by the PROMOTIC application.
After the preconfiguration is created, the "PmaCommGroup > Parameters > Communication refresh rate [ms]" configurator will be set to this value.
Panel titleDisplayed in the panel header

History:
Pm8.03.13: Created
PROMOTIC 9.0.27 SCADA system documentation MICROSYS, spol. s r.o.