Preconfiguration "PmOmronC - Communication set with data and panel"

Communication driver configuration PmOmronC - Driver for communication with OMRON PLC devices with protocol for C-mode.

This preconfiguration can be activated when creating a new object (e.g. by "New object ..." in the local object menu or by pressing the Insert key after selecting the object) and is included in the group: "/ Communication / PLC devices and meters / Omron - PLC device".
This preconfiguration can be created in the object: PmaFolder or PmaRoot.

The preconfiguration creates an object of the PmaComm type and a testing data set. Also the panel with complex Pmg objects is created for displaying the status.

- The preconfiguration creates an object of the PmaFolder type containing PmaComm object with PmaCommGroup subobject and following objects: PmaPanel, PmaData.
- The preconfiguration is created including the panel (object of the PmaPanel type) is functional also as Web panel.
- The panel is used for communication testing and it is not essential for the communication functionality.


In the PmaComm object named "Comm" the communication parameters are set (Network address, ...). The required data is defined in the PmaData object and connected via the ExtComm to the PmaCommGroup object.
These configurators can be set before the preconfiguration is created:
The name of created objectName of the object created in the Pma objects tree. The maximum name length is 30 characters. This is a system name, so it must contain only alphanumeric and must not contain any diacritics (i.e. national dependent characters), empty string, spaces and the first character must not be a number.
Default: "CommOmronC"
Serial portSelection of the communication serial port.
The value can be change by the OpenPort method.
The value can be detected by method GetProtParam("SerPort").
After the preconfiguration is created, the "PmaComm > Setting the parameters of the serial link > Serial port" configurator will be set to this value.
Not set - The object is not connected to any port after the application is launched and the serial port can be selected dynamically by the algorithm (by the PmaComm.OpenPort method).
COM1, COM2,..,COM66 - The specified serial port is opened after the application is launched. This port must be correctly configured and accessible in Windows OS (no one can use it).
For serial link each PmaComm object must have defined another communication port. For example, if one PmaComm object communicates through COM1, then next PmaComm object can communicate for example through COM2 (COM3, ...) but it mustn't communicate through COM1.
Baud rateSelection of the baud rate (bps, bit per second).
This configurator sets the initial value of the BaudRate property.
After the preconfiguration is created, the "PmaComm > Setting the parameters of the serial link > Baud rate" configurator will be set to this value.
110
300
600
1200
2400
4800
9600
14400
19200
38400
57600
115200
128000
256000
Communication refresh rate [ms]The period in milliseconds to be used for reading the current data by the PROMOTIC application.
After the preconfiguration is created, the "PmaCommGroup > Parameters > Communication refresh rate [ms]" configurator will be set to this value.
Create examples of testing dataA set of exemplary data is created
Create panel for test dataCreates panel that monitors the statistics of communication values
Panel titleDisplayed in the panel header

History:
Pm8.03.01: Created