Preconfiguration "PmModbusMr - LUMEL Power network meter with Ethernet and recording ND30 (NR30) (Modbus TCP/IP) - Communication set with data and panel"

Communication by the Modbus TCP/IP protocol with ND30 (NR30) device.
Measurement devices manufactired by the LUMEL company https://www.lumel.com.pl

The valid TCP-IP address must be set for the device according to the corresponding network environment. The configuration is described in the user manual supplied by the manufacturer.

This preconfiguration can be activated when creating a new object (e.g. by "New object ..." in the local object menu or after pressing the Insert key after selecting the object) and is included in the group: "/ Communication / Modbus".
This preconfiguration can be created in the object: PmaFolder or PmaRoot.

- The preconfiguration creates an object of the PmaFolder type containing PmaComm object with PmaCommGroup subobject and following objects: PmaPanel, PmaData, PmaTrendGroup.
- The preconfiguration is created including the panel (object of the PmaPanel type) is functional also a Web panel.
- The panel is used for communication testing and it is not essential for the functionality.


These configurators can be set before the preconfiguration is created:
The name of created objectName of the object created in the tree of Pma objects. The maximum name length is 30 characters. This is a system name, so it must contain only alphanumeric and must not contain any diacritics, empty string, spaces and the first character must not be a number.
Default: "Lumel"
Network addressNetwork address to which the communication will be connected. The address can be entered by both IP address (e.g. 192.168.0.15) or by name (e.g. server11).
Macro expression can be used for input (it is evaluated after starting the application).
After the preconfiguration is created, the "PmaComm > Setting the parameters of the Ethernet-client > Network address" configurator will be set to this value.
Communication refresh rate [ms]The period in milliseconds to be used for reading the current data by the PROMOTIC application.
After the preconfiguration is created, the "PmaCommGroup > Parameters > Communication refresh rate [ms]" configurator will be set to this value.
Panel titleDisplayed in the panel header

History:
Pm9.00.17: Created
PROMOTIC 9.0.18 SCADA system documentation - MICROSYS, spol. s r.o.