Preconfiguration "PmMBus - Calmex meter - Communication set with data and panel"

Configuration of the PmMBus communication driver with test panel.

This preconfiguration can be activated when creating a new object (e.g. by "New object ..." in the local object menu or by pressing the Insert key after selecting the object) and is included in the group: "/ Communication / Protocols and other communications / M-BUS".
This preconfiguration can be created in the object: PmaFolder or PmaRoot.

The preconfiguration creates an object of the PmaComm type and a testing data set. Also the panel with complex Pmg objects is created for displaying the status.

- The preconfiguration creates an object of the PmaFolder type containing PmaComm object with PmaCommGroup subobject and following objects: PmaPanel, PmaData.
- The preconfiguration is created including the panel (object of the PmaPanel type) is functional also as Web panel.
- The panel is used for communication testing and it is not essential for the communication functionality.
These configurators can be set before the preconfiguration is created:
The name of created objectName of the object created in the Pma objects tree. The maximum name length is 30 characters. This is a system name, so it must contain only alphanumeric and must not contain any diacritics (i.e. national dependent characters), empty string, spaces and the first character must not be a number.
Default: "MBusCalmex"
Serial portSelection of the communication serial port.
The value can be change by the OpenPort method.
The value can be detected by method GetProtParam("SerPort").
After the preconfiguration is created, the "PmaComm > Setting the parameters of the serial link > Serial port" configurator will be set to this value.
Not set - The object is not connected to any port after the application is launched and the serial port can be selected dynamically by the algorithm (by the PmaComm.OpenPort method).
COM1, COM2,..,COM66 - The specified serial port is opened after the application is launched. This port must be correctly configured and accessible in Windows OS (no one can use it).
For serial link each PmaComm object must have defined another communication port. For example, if one PmaComm object communicates through COM1, then next PmaComm object can communicate for example through COM2 (COM3, ...) but it mustn't communicate through COM1.
Default meter addressThe device address in the M-Bus network. See: Default meter address.
Create panel "Meter value information"Creates the PmaCommMsg object and panel for detecting information regarding the connected device
Create panel for test dataCreates panel that monitors the statistics of communication values

History:
Pm8.02.00: Created