Communication driver configuration Pm3964 - Driver for communication with Simatic devices by 3964, 3964R or RK-512 protocol.
 
This preconfiguration can be activated when creating a new object (e.g. by "New object" in the local object menu or after pressing the Insert key after selecting the object) and is included in the group: " / Communication / 3964 and RK512 communication protocol".

This preconfiguration can be used with the objects: PmaFolder or PmaRoot.

 
Preconfiguration for serial link.

The created preconfigured connection is functional usually immediately. Otherwise it is necessary to obtain the connection parameters specified by the device manufacturer or in the documentation: Pm3964 - Driver for communication with Simatic devices by 3964, 3964R or RK-512 protocol.

These configurators can be set before the preconfiguration is created:
The name of created objectName of the object created in the tree of Pma objects. The maximum Pma object name length is 31 characters. This is a system name, so it must contain only alphanumeric and must not contain any diacritics, empty string, spaces and the first character must not be a number.

Default: "Comm"

Serial portSelection of the communication serial port.

The value can be change by the OpenPort method. The value can be detected by method GetProtParam(""SerPort"").

After this preconfiguration is created, the configurator is se to: PmaComm > Setting the parameters of the serial link > Serial port.

Not set - The object is not connected to any port after starting the application and the serial port can be selected dynamically by the algorithm (by the PmaComm.OpenPort method).
COM1, COM2,..,COM66 - The specified serial port is opened after starting the application. This port must be correctly configured and accessible in the OS Windows (no one can use it).

For serial link each PmaComm object object must have defined another communication port. For example, if one PmaComm object communicates through COM1, then next PmaComm object can communicate for example through COM2 (COM3,..) but it mustn't communicate through COM1.

Create examples of testing data for RK512Create examples of testing data for RK512
Create examples of testing data for 3964, 3964RCreate examples of testing data for 3964, 3964R