Promotic

Cell - configuration window

Description:
The window serves for setting the parameters of selected table cell.
This configuration window can be opened on the "PmgWTable > Cells" tab.
Configurators:
Cell rangeSpecifies the range of cells where the setting of selected property will be applied.
0 - single cell - Sets the property value only in a single cell. The cell position is defined by row number and column number.
1 - cell range in a single row - Sets the property value in a group of cells in a single row. The range of cells is defined by row number and the numbers of the start and end columns.
2 - cell range in a single column - Sets the property value in a group of cells in a single column. The cell range is defined by column number and the numbers of the start and end rows.
3 - cell range - Sets the property value in a group of cells. The cell range is defined by the index of the start and end rows and the index of the start and end columns.
RowRow index
ColumnColumn index
PropertyCell property type
0 - Cell text
1 - Horizontal alignment
2 - Vertical alignment
3 - Background color
4 - Text color
5 - Enable cell editing
Cell textCell text setup
Horizontal alignmentHorizontal cell text alignment setup
0 - left
1 - Center
2 - Right
Vertical alignmentVertical cell text alignment setup
0 - Up
1 - Center
2 - Down
Background colorCell background color setup
Text colorCell text color setup
Enable cell editingEnable editing of text in selected cell.
Note: Enable cell editing is relevant only if the "Edit mode" configurator on the "Table" tab is set to value 3.
See also:

History:
Pm9.00.00: Created