Preconfiguration "eWON - Communication with eWON industrial routers - Communication set with data and panel"

Configuration of the communication with eWON.

This preconfiguration can be activated when creating a new object (e.g. by "New object ..." in the local object menu or by pressing the Insert key after selecting the object) and is included in the group: "/ Communication / PLC devices and meters / eWON - PLC device".
This preconfiguration can be created in the object: PmaFolder or PmaRoot.

The preconfiguration allows data export and processing from defined variable in requested format nad time range.

The "PanelTest" test panel is used for testing and displaying of received data. The configurators can be used to assemble desired command parameter. Assembled parameter is displayed in text and can be modified further. (Additional options and parameters are published in manufacturer's documentation.)

Calling the "RequestData" method (of the PmaFolder object) with corresponding parameters the onStep event is triggered of the PmaSequencer object. Here the HttpRequest object is used for communication with the device. (Login name and password shown in this example corresponds to manufacturer's original setup: adm and adm) The received data is processed in the "ReplyCsv" method. This method can be modified as needed.

The preconfiguration was tested with the connection managed by the eCatcher software tool (available for download from manufacturer's Web page). This software tool initializes akterý inicializuje and manages remote access via Talk2M VPN network and allows remote connection to all devices connected to the corresponding eWON router.
These configurators can be set before the preconfiguration is created:
The name of created objectName of the object created in the Pma objects tree. The maximum name length is 30 characters. This is a system name, so it must contain only alphanumeric and must not contain any diacritics (i.e. national dependent characters), empty string, spaces and the first character must not be a number.
Default: "eWon"
Network addressNetwork address of the remote device (e.g. of the PLC device), to which the communication will be connected.
The address can be entered as:
- IPv4 full address (e.g. "192.168.0.15")
- IPv4 address of this computer (i.e. "127.0.0.1")
- IPv4 computer name (e.g. "server11")
- IPv4 name of this computer (i.e. "localhost")
- IPv6 full address (e.g. "2a02:c38:8136:800a:37a:ab66:6fc9:accd")
- IPv6 address of this computer (i.e. "::1")
Name of the variableVariable name in the device.
Create test panelCreates panel used for communication testing and displaying of received data

History:
Pm8.02.03: Created