WndHistory - method of object PmaAlarmGroup

Description:
Operations with the history viewer of an alarm group.

This method is obsolete (but functional) and is replaced by the concept of opening windows by the OpenView methods, that are more general, capable of for example:

- opening the viewer in the workspace (in the PmaWorkspace object)
- opening the viewer for the Web client (see Web alarms)

See The example of alarm viewer opening.

Syntax:
Boolean WndHistory(Long nOper, [String sFilter])
Calling:
oAl.WndHistory nOper, sFilter
Parameters:
nOper(Long) Type of the operation with the window
0 - Close the window. The method returns true if the window has actually been closed (it was opened before that).
1 - Open the window. The method returns true if the window has actually been opened (it was closed before that).
2 - Check of opening the window. The method returns true if the window is opened.
sFilter[optional] (String) Filtering text that specifies which alarms are to be included into the desired output.

Different filtration fields can be used simultaneously, the alarm then must comply with all of them (e.g. "desc:FIQ100;priority.ge:5;").

The filtering text xx cannot be empty string (e.g. it is not possible to enter "desc:;").

Entries are in KeyVal format, for example "desc:Test2;records:50;".

 

The folowing types of filtration texts exist ("field" represents some of the alarm columns):

"field:xx;" means that the corresponding alarm field must be equal to the value of xx.
"field:#eq:xx;" means that the corresponding alarm field must be equal to the value of xx. If the corresponding alarm field is to be equal to one of several texts, then can be entered multiple texts separated by #or:.
"field:#begin:xx;" means that the corresponding alarm field must begin with the text xx. If the corresponding alarm field is to begin with some of several texts, then can be entered multiple texts separated by #or:.
"field:#in:xx;" means that the corresponding alarm field must contain the textxx. If the corresponding alarm field is to contain some of several texts, then can be entered multiple texts separated by #or:.
"field:#le:xx;" means that the corresponding alarm field must be less or equal to xx.
"field:#ge:xx;" means that the corresponding alarm field must be greater or equal to xx.
 

Note! If the field begins with the text s., then this is the setting hidden from the enduser in the alarm viewer and it is used to set the definite script filtration independent on end user settings. Both filtration type fields can be used for a single column simultaneously. In order to let the alarm pass the filter it must comly to both filtering fields. This can be handy for definite script filtrations (independent on enduser) and also for setting the initial state of user defined filtration (that can be modified by the enduser). For example s.source:#begin:Boiler;source:Boiler1;.

 
"area:#oper:xx;" (optional) - Show alarms with area observing the defined operation #oper:xx. The part of filter dependent on user setting in the alarm viewer. For example "area:BoilerPlant1;" or "area:#eq:BoilerPlant1;" or "area:#eq:BoilerPlant1#or:BoilerPlant2;" or "area:#begin:BoilerPlant;".
"s.area:#oper:xx;" (optional) - Show alarms with area observing the defined operation #oper:xx. The part of filter hidden from the user in the alarm viewer. For example "s.area:BoilerPlant1;" or "s.area:#eq:BoilerPlant1;" or "s.area:#eq:BoilerPlant1#or:BoilerPlant2;" or "s.area:#begin:BoilerPlant;".
"source:#oper:xx;" (optional) - Show alarms with source observing the defined operation #oper:xx. The part of filter dependent on user setting in the alarm viewer. For example "source:Boiler;" or "source:#eq:Boiler;" or "source:#eq:Boiler1#or:Boiler2;" or "source:#begin:Boiler;".
"s.source:#oper:xx;" (optional) - Show alarms with source observing the defined operation #oper:xx. The part of filter hidden from the user in the alarm viewer. For example "s.source:Boiler;" or "s.source:#eq:Boiler;" or "s.source:#eq:Boiler1#or:Boiler2;" or "s.source:#begin:Boiler;".
"desc:#oper:xx;" (optional) - Show alarms with description (desc) observing the defined operation #oper:xx. The part of filter dependent on user setting in the alarm viewer. For example "desc:FIQ101;" or "desc:#eq:FIQ101;" or "desc:#eq:FIQ101#or:FIQ102;" or "desc:#begin:FIQ;".
"s.desc:#oper:xx;" (optional) - Show alarms with description (desc) observing the defined operation #oper:xx. The part of filter hidden from the user in the alarm viewer. For example "s.desc:FIQ101;" or "s.desc:#eq:FIQ101;" or "s.desc:#eq:FIQ101#or:FIQ102;" or "s.desc:#begin:FIQ;".
"comment:#oper:xx;" (optional) - Show alarms with comment observing the defined operation #oper:xx. The part of filter dependent on user setting in the alarm viewer. For example "comment:correction;" or "comment:#eq:correction;" or "comment:#eq:correction#or:test;" or "comment:#begin:correction;".
"s.comment:#oper:xx;" (optional) - Show alarms with comment observing the defined operation #oper:xx. The part of filter hidden from the user in the alarm viewer. For example "s.comment:correction;" or "s.comment:#eq:correction;" or "s.comment:#eq:correction#or:test;" or "s.comment:#begin:correction;".
"priority:#oper:xx;" (optional) - Display alarms whose priority complies with the operation #oper:xx. The part of filter dependent on user setting in the alarm viewer. For example "priority:5;" or "priority:#eq:5;" or "priority:#le:5;" or "priority:#ge:5;".
"from:xx;" (optional) - Display the alarms with time of creation (timeon) greater or equal to time "xx". The time is entered as time(YYYY.MM.DD-hh:mm:ss.mmm), e.g. "from:time(2018.07.28-14:30:00.000);". The Time-range allows to narrow down the searched alarm set (alarms outside the time-range are not tested).
"to:xx;" (optional) - Display the alarms with time of creation (timeon) less or equal to time "xx". The time is entered as time(YYYY.MM.DD-hh:mm:ss.mmm), e.g. "to:time(2018.07.28-15:00:00.000);". The to time can be entered also by the now keyword, which means the current time (at the moment of calling), e.g. to:now. The Time-range allows to narrow down the searched alarm set (alarms outside the time-range are not tested).
"timerange:xx;" (optional) - Display the alarms with the creation time (timeon) belonging to specified time interval For selecting the time interval by timerange, the value of from or to must be defined, where the timerange allows to compute the missing limit of the time interval. Thus the time interval can be defined by the following pairs: from - to, from - timerange or to - timerange. For example to:now;timerange:30m;. Time-range allows to reduce the portion of alarm items to be searched (alarms outside the time-range are not tested).

The time-range can be entered as integer followed by time unit sign (without space). Valid time units are: w = week, d = day, h = hour, m = minute, s = second. For example timerange:12h; or timerange:90m;.

Note:
The WndHistory method opens the viewer always in new independent window.
Example:
Opening the alarm history viewer, for example in the panel button in the onButtonUp event. "/alarms" is the path to the PmaAlarmGroup object.
JavaScriptVBScriptSelect and copy to clipboard

var oAl = pMe.Pm("/alarms");
oAl.WndHistory(1);
The WndHistory method can be replaced by the OpenView method:
JavaScriptVBScriptSelect and copy to clipboard

pMe.PmPanel.OpenView("/alarms/#history", "target:_blank;");