PmgPipe - elbow down/right

Creates the PmgPipe object.

This preconfiguration can be activated when creating a new Pmg object and is included in the group: "/ Pipes / Pipeline (PmgPipe)".
PmgPipe:
The name of created objectName (identifier) of the Pmg object. It is used for obtaining the Pmg object by the PmgObject.Items method.
This configurator sets the initial value of the Name property.
The maximum name length is 30 characters.
This is a system name, so it must contain only alphanumeric and must not contain any diacritics (i.e. national dependent characters), empty string, spaces and first character must not be a number.
WidthWidth of the pipeline
ColorColor of the pipeline inside.
This configurator sets the initial value of the ColorItem property.
Border widthPipeline border width. (in pixels).
RadiusRadius of the pipeline curve (in pixels).
PatternImage of the stream pattern.
This configurator sets the initial value of the StreamFile property.
It is recommended to always use the path with #pmres: or #appres:.
Macro expression can be used for input (it is evaluated while the window is opening).

- If the template is an empty string, then it is not displayed.
- Can be used the preset stream patters which are supplied in the PROMOTIC system in the #pmres:Img folder - see Stream - Images. Except these patterns it can be used any other pattern (file with image in the svg, png, jpg, bmp ... format).
- The pattern is expanded into the whole area of the pipeline and therefore the pattern has to be created so as it is bound smoothly to itself.
- The image must be always created so that it is oriented to the horizontal pipeline by its pattern. If this image is used in the vertical pipeline, then it is rotated by 90° before its expansion automatically.
- Each period (see StreamPeriod) the image is moved by 3 pixels, and therefore it is appropriate to use the images width of 9 or more pixels (the height can be whichever).
DirectionDirection of the stream.
This configurator sets the initial value of the StreamDirection property.
Macro expression can be used for input (it is evaluated while the window is opening).
1 = Streamed from the left
2 = Streamed from above
4 = Streamed from the right
8 = Streamed from below

History:
Pm8.03.04: Created
PROMOTIC 9.0.29 SCADA system documentation MICROSYS, spol. s r.o.

Send page remarkContact responsible person
© MICROSYS, spol. s r.o.