Promotic
WikipediaLinkedInYoutubeTwitterFacebook

Blink - method of object PmiItem

Description:
By calling the method is it possible to start/stop blinking of the item. If it is called repeatedly, it enables to change blinking parameters or to stop blinking.
Syntax:
Blink(nDelay As Integer, nPeriod As Integer)
Calling:
oItem.Blink delay, period
Parameters:
nDelay(Integer) Length of blinking
-1 - infinite long
0 - don't blink = stop blinking
>0 - blink for the assigned time in seconds
nPeriod(Integer) Period of blinking. It is set as the multiple of the panel refresh period. For example, 2 means that blinking happens every second period of the panel refresh.
Note:

This method is not functional for Web Panels.

This method is not functional for PmiRoot graphic item.

Example:
It runs blinking for infinite time. The period of blinking is in each panel refresh.
oItem.Blink -1, 1