Promotic
WikipediaLinkedInYoutubeTwitterFacebook

Text - page of object PmgString

Description:
Text properties.
Configuration items:
Value

This configurator sets the initial value of the property Value.

Macro expression can be used for input ($.text ..) (it is evaluated while the window is opening).

If it is written to this property and if this property is linked to the data binding PP, AP, SP, OP or GP, then the value is transferred also into the source of this binding.

FontFont of the text.

This configurator sets the initial value of the property FontId.

ColorText color

This configurator sets the initial value of the property ColorText.

Alignment horizontalHorizontal alignment of the text
Left
Center
Right
Alignment verticalVertical alignment of the text
Up
Center
Down
RotateText rotation (is only in PmgString, PmgNumber, PmgButton and PmgButtonState objects)
Do not rotate
Left - Text will be rotated 90 degrees counterclockwise
Down - Text will be rotated upside down
Right - Text will be rotated 90 degrees clockwise
Type of text shadingSelection of the text shading type.
None - Text is not shaded
Right down - Text is shaded to the right bottom
Shading colorSelection of the color of the text shading
Multi-line textIf checked, then the text is displayed on multiple rows.

This configurator sets the initial value of the property Multiline.

Display as passwordIf checked, then, the text is displayed as a password, i.e. * char (asterisk) is displayed instead of the entered char.
Value format typeIt is possible to enter simple formula for formatting. The more complex formula (e.g. for a multiple input) is entered by means of the "F - Data binding to the formatted string" data binding.

Tip: To display a number with fixed number of decimal places with the decimal point always on the same position, use the Horizontal alignment "Right" (you can add spaces at the and of the formula, to avoid placing the number to the right).

None - The formatting is not used
C language formatting - C language format. See C language string format specification.
Format valuesFormatting according to the syntax of format type value.

Macro expression can be used for input (it is evaluated while the window is opening).

Type of editingIf editing is enabled in this configurator, then the object can be edited in the runtime mode by pressing the Enter key or mouse doubleclick.
Editing disabled - The value can be edited directly in this object.
Editing on value location - The value can be edited directly in this object.
Editing in auxiliary window - When editing the value, a new window is opened.
Edit box titleText of the window title that is displayed for editing the value.

Macro expression can be used for input ($.text ..) (it is evaluated while the window is opening).

This configurator is visible only if Type of editing = Editing in auxiliary window.

Buttons on the right side of the configuration window of each Pmg object:

History:
Pm9.00.02: Fixed bug: The Alignment horizontal configurator with "Right" value did not work correctly in local panel.
PROMOTIC 9.0.7 SCADA system documentation - MICROSYS, spol. s r.o.

Send page remarkContact responsible person
© MICROSYS, spol. s r. o.Tavičská 845/21 703 00 Ostrava-Vítkovice