MultilineIf checked, then the text can be on more lines. This text can be aligned by the Alignment configurator.
New line by Enter (default Ctrl+Enter)If checked, then the new line is inserted after pressing the Enter (Ctrl+Enter) key. This configurator is meaningful only if Multiline is checked.
AutoHScrollIf checked, then after filling in the EditBox, the text is scrolled left if new chars are entered.
Automatic row shiftIf checked, then after filling in, the rows are scrolled up (on entering new lines). Thus the last line is displayed an the bottom of the item.
Horizontal scrollbarIf checked, then a horizontal scrollbar is entered into the item.
Vertical scrollbarIf checked, then a vertical scrollbar is entered into the item.
Display as passwordIf checked, then the text is displayed as a password, i.e. * char (asterisk) is displayed instead of the entered char.
UpperCaseIf checked, then only upper cases are inserted (lower cases are converted to upper cases).
LowerCaseIf checked, then only lower cases are inserted (upper cases are converted to lower cases).
Read onlyIf checked, then editing the text that is displayed in this item, is disabled.
Only non-negative integerIf checked, then neither a decimal number nor a letter can be entered.
Return initial data on Esc keyIf checked, then the overwritten value is restored after pressing the Esc key (editing isn't terminated) on entering new value (overwriting another value) in the running application.
Write data on Enter keyIf checked, then the entered value is written into the data binding of the Text configurator (if a data binding is defined) after pressing the Enter key on entering new value (overwriting another value) in the running application.
Write data on losing focusIf checked, then the entered value is written even on losing the focus on entering new value (overwriting another value) in the running application.

This configurator cannot be set if configurator is checked Before sending data ask for confirmation.

Before sending data ask for confirmationIf checked, then then, once the editing is finished the confirmation window is displayed (before the value itself is written into the item).

This configurator cannot be set if configurator is checked Write data on losing focus.

Move to next item on Enter keyIf checked, then after pressing the Enter key in the running application the focus is moved to the next graphic item in the order.
Buttons on the right side of the configuration window of each item: