Preconfigurations PmNET0 - Minimal set of the PmComm object

Communication driver configuration PmNET0 - Driver for communication with PROMOTIC by NET0 protocol
 
This preconfiguration can be activated when creating a new object (e.g. by "New object" in the local object menu or by pressing the Insert key after selecting the object) and is included in the group: " / Communications / NET0 protocol".

This preconfiguration can be used with the objects: PmFolder or PmRoot.

 
Preconfiguration for serial port.

The created preconfigured connection is usually functional immediately. In other cases, it is necessary to obtain the connection parameters specified by the device manufacturer or in the documentation: PmNET0 - Driver for communication with PROMOTIC by NET0 protocol.

These configurators can be set before the preconfiguration is created:
The name of created objectName of the object created in the application object tree. This is a system name and must not contain empty string, diacritics, spaces and the first character must not be a number.

Default: "Comm"

Serial portSelection of the communication serial port.

After this preconfiguration is created, the configurator is se to: PmComm > Settings of the serial link parameters > Serial port.

Not set - The object is not connected to any port at the start of the application and the serial port can be selected dynamically by the algorithm (by the PmComm.OpenPort method).
Modem - The object is meant for the data transfer over the dialed phone line (over the PmModem object). The serial port is assigned by the PmModem.SetPmComm method or by the PmComm object configurator of the PmModem object.
COM1, COM2,..,COM66 - The specified serial port is opened at the start of the application. This port must be correctly configured and accessible in the OS Windows (no one can use it).

For serial link each PmComm object must have defined another communication port. For example, when one PmComm object communicates through COM1, then next PmComm object can communicate for example through COM2 (COM3,..) but it mustn't communicate through COM1.

Baud rateSelection of the baud rate (bps, bit per second).

This configurator sets the initial value of the property BaudRate.

After this preconfiguration is created, the configurator is se to: PmComm > Settings of the serial link parameters > Baud rate

110
300
600
1200
2400
4800
9600
14400
19200
38400
57600
115200
128000
256000
Parity Parity selection. Appropriate value for the device, which it is communicated with, must be selected.

This configurator sets the initial value of the property Parity.

After this preconfiguration is created, the configurator is se to: PmComm > Settings of the serial link parameters > Parity

NO
ODD
EVEN
Number of stop bits Number of stop bits selection Appropriate value for the device, which it is communicated with, must be selected.

This configurator sets the initial value of the property StopBits.

After this preconfiguration is created, the configurator is se to: PmComm > Settings of the serial link parameters > Number of stop bits

1 stopbit
1.5 stopbit
2 stopbit
This computer number (ncp)

After this preconfiguration is created, the configurator is se to: PmComm > Parameters > Protocol parameters

Opposite computer number (ncp)

After this preconfiguration is created, the configurator is se to: PmCommMsg > Parameters > Message parameters