Promotic
WikipediaLinkedInYoutubeTwitterFacebook

PROMOTIC - Application references

In the list of selected references you can find applications from various areas of the process automation that were implemented by the PROMOTIC system. We'll be glad to extend this list by Your interesting applications that you've created by the PROMOTIC system. You can send us the basic information by filling in this form.

 

Detailed PROMOTIC application references

 

Selected references of the PROMOTIC system include the following applications:

 
  provided for this country (countries)
 
 
Sorting by the application type
 
Choice has no reference items Count of reference items in selection
 

Monitoring and evaluation of machinery performance in Danfoss a.s. production plant, Slovakia

Hardware:1xPC Sever + 12x PC Client + 15x WebClient, MS SQL server Control stations: , 24xPLC typu Hitachi, Sprecher_Schuh, Simatic, Mitsubishi
Implementation:MICROSYS, spol. s r.o.
Date of commission:2015

Measurement and evaluation of energy consumption - Gemini B building, Czech republic

Hardware:1x PC + 1x WebClient Control stations: 200x heat, water, electricity meters
Implementation:MICROSYS, spol. s r.o., ENBRA a.s
Date of commission:2015

Technology monitoring Glanzstoff, Lovosice, Czech republic

Hardware:1x PC + 10x WebClient, MS SQL server Control stations: 25x Simatic
Implementation:MICROSYS, spol. s r.o.
Date of commission:2015

Energy monitoring, consumption control - Solaris Poznaň, Poland

Hardware:1x PC Control stations: 65x heat, water, electricity meters
Implementation:MICROSYS, spol. s r.o., Astat sp. z o.o.
Date of commission:2015

Manufacturing information system in United Energy heating plant - Komořany u Mostu, Czech republic

Hardware:1x PC server, 5x PC client + 30Web client, MS SQL server Control stations:80x PLC typu Allen-Bradley, Foxboro, Simatic, Schneider, Honeywell
Implementation:MICROSYS, spol. s r.o.
Date of commission:2015

Vibration monitoring on Darkov mine - OKD, Czech republic

Hardware:1x PC server Control stations:5x PLC Bernecker&Reiner
Implementation:MICROSYS, spol. s r.o., DIF spol. s r.o
Date of commission:2015

Emission monitoring - Kazaň, Russia

Hardware:1x PC Control stations: Simatic S7-300
Implementation:MICROSYS, spol. s r.o., RMT s.r.o
Date of commission:2015

Emission monitoring - Vitošov, Czech republic

Hardware:1x PC + 1x Web client Control stations: Simatic S7-300
Implementation:MICROSYS, spol. s r.o., RMT s.r.o
Date of commission:2015

Monitoring of K3 boiler and desulphurization, Actherm Chomutov heating plant, Czech republic

Hardware:12x PC, MS SQL server Control stations:
Implementation:MICROSYS, spol. s r.o.
Date of commission:2015

Reconstruction of water treatment plant bridges Hrádek nad Nisou, Czech republic

Hardware:PC OS Windows 7 Control stations: 3x Schneider Electric Modicon M340, Schneider Twido, Modbus
Implementation:MARTIA a.s. www.martia.cz
Date of commission:2015

Expansion of water treatment technology Chrastava, Czech republic

Hardware:PC OS Windows 7 Control stations: 2x Schneider Electric Modicon M340, Modbus
Implementation:MARTIA a.s. www.martia.cz
Date of commission:2015

Remote meter readings of exchange stations - stage 1, Czech republic

Hardware:PC OS Windows Server 2012 R2, MS SQL Server, 3x WebClient Control stations: 150x PmMBus
Implementation:MARTIA a.s. www.martia.cz
Date of commission:2015

Decentralization of heat source in Jablonec nad Nisou, Czech republic

Hardware:PC OS Windows Server 2012 R2, 2x WebClient Control stations: 31x Siemens Climatix, Modbus
Implementation:MARTIA a.s. www.martia.cz
Date of commission:2015

Monitoring of force (tension) on the manufacturing line, Czech republic

Hardware:1xPC Control stations: Papouch AD4ETH, tenzometr KISTLER
Implementation: CTS www.ctscorp.com
Date of commission:2015

Monitoring and control of production line BLDC, Bosch České Budějovice, Czech republic

Hardware:1xPC, MS SQL server Control stations: PLC Bosh
Implementation:MICROSYS, spol. s r.o.
Date of commission:2014

Monitoring and control of production line BLDC, Bosch, Slovakia

Hardware:1xPC, 1xWeb klientControl stations: datalogger
Implementation:MICROSYS, spol. s r.o., ECM ECO monitoring s.r.o.
Date of commission:2014

Emission monitoring - Wloclawek, Poland

Hardware:1xPC Control stations: Simatic S7-300
Implementation:MICROSYS, spol. s r.o., RMT s.r.o
Date of commission:2014

Emission monitoring, Algeria

Hardware:1xPC Control stations: Simatic S7-300
Implementation:MICROSYS, spol. s r.o., RMT s.r.o
Date of commission:2014

Emission monitoring, Uzbekistan

Hardware:1xPC Control stations: Simatic S7-300
Implementation:MICROSYS, spol. s r.o., RMT s.r.o
Date of commission:2014

Emission monitoring, Turkish

Hardware:1xPC Control stations: Simatic S7-300
Implementation:MICROSYS, spol. s r.o., RMT s.r.o
Date of commission:2014

Monitoring and control of printing heads on packaging line Biocel Paskov, Czech republic

Hardware:1xPC server, 10xWeb klient Control stations:
Implementation:MICROSYS, spol. s r.o.
Date of commission:2014

Reconstruction of lab building in Chemopetrol, Czech republic

Hardware:PC OS Windows 7 Control stations: 1x Siemens Desigo, BACnet
Implementation:MARTIA a.s. www.martia.cz
Date of commission:2014

Replacement of control systems in exchange stations in Vrchlabí, Czech republic

Hardware:PC OS Windows 7, 2x WebClientControl stations: 61x Siemens Climatix, Modbus, PmMBus
Implementation:MARTIA a.s. www.martia.cz
Date of commission:2014

Inovative system of boiler control, Slovakia

Hardware:1x PC OS Windows Control stations: AMiT DIRAS, ADiS
Implementation:Technická univerzita v Košiciach www.tuke.sk
Date of commission:2014

Monitoring and control system of melting furnace "KORBOMAT", Eutit Stará Voda, Czech republic

Hardware:2x PC Control stations:1x Schneider Electric Modicon M340
Implementation:ZPA-RP, a.s. www.zpa-rp.cz
Date of commission:2014

Monitoring and control system of High Voltage switching stations, Momentive Sokolov, Czech republic

Hardware:2x PC Control stations:1x Schneider Electric Modicon Quantum HSBY, 7x Schneider Electric Modicon x80
Implementation:ZPA-RP, a.s. www.zpa-rp.cz
Date of commission:2014

Control and monitoring system of steam condensation turbine with regulated output, EC Mostek, Czech republic

Hardware:1x SIMATIC HMI IPC 477C Control stations:1x Siemens S7-317PNDP, 3x Siemens ET200M, Woodward 505E
Implementation:ZPA-RP, a.s. www.zpa-rp.cz
Date of commission:2014

Control and monitoring system of couterpressure steam turbine CSTG 1, EC Pila FED Návsí, Czech republic

Hardware:1x SIMATIC HMI IPC 477C Control stations:1x Siemens S7-315PNDP, 2x Siemens ET200M
Implementation:ZPA-RP, a.s. www.zpa-rp.cz
Date of commission:2014

Control and monitoring system of couterpressure steam turbine STG II, Dalkia Mariánské Lázně, Czech republic

Hardware:1x SIMATIC HMI IPC 477C Control stations:1x Siemens S7-314PNDP, 1x Siemens ET200M
Implementation:ZPA-RP, a.s. www.zpa-rp.cz
Date of commission:2014

Visualization of free-time activity building technologies. Small water powerplant, heating, electricity and HVE - Kalikovský Mlýn s.r.o, Czech republic

Hardware:1x PC OS Windows XP, 1x WEB client Control stations: AMiT Amap99, 2x Amiris99, ART267A, Amini2D, Amini2, 6x Amini-E
Implementation:Miroslav Legutko www.legutko.cz
Date of commission:2013

Emission monitoring Precheza Přerov, Czech republic

Hardware:1xPC Control stations: PLC MicroLogix 1100
Implementation:MICROSYS, spol. s r.o.
Date of commission:2013

Monitoring of 32 dual fuel generators, Ghana, Africa

Hardware:1xPC Control stations:
Implementation:MICROSYS, spol. s r.o., ComAp a.s. www.comap.cz
Date of commission:2013

Monitoring and evaluation of machine performance in the Danfoss a.s. company., Zlaté Moravce, Slovakia

Hardware:1xPC server + 6xPC, 10x WebClient, MsSQL server Control stations: Hitachi, Sprecher_Schuh
Implementation:MICROSYS, spol. s r.o.
Date of commission:2013

Medi-Globe pressure measurement visualisation and evaluation Hranice na Moravě, Czech republic

Hardware:1xPC Control stations:
Implementation:MICROSYS, spol. s r.o.
Date of commission:2013

REZA visualization system for Czech Railways, Czech republic

Hardware:6x PC (Win) Control stations:REZA
Implementation:OHL ŽS a.s. www.ohlzs.cz
Date of commission:2013

Monitoring and Control of Power Substation, Greece

Hardware:1x PC OS Windows 7, OPC Control stations: 1xSEL451, 1xSEL787, 1xSEL751 and 4xSEL751A
Implementation:PSP www.psp.com.gr
Date of commission:2013

Complete control and monitoring system ID-6.2 - Bautzen airport, Germany

Hardware:1x PC OS Windows XP, 2x WEB client Control stations: ICPDAS ET7052, RFGSM
Implementation:RSI SOFT s.r.o. www.rsi-soft.cz
Date of commission:2013

Acquisition of data from ultrasound level meters, Czech republic

Hardware:1x PC OS Windows (XP,Vista, 7) Control stations: Dinel ULM-53L, Dinel URC-485
Implementation:Dinel, s.r.o. www.dinel.cz
Date of commission:2013

Complete control and monitoring system ID-6.2 - Magnitogorsk airport, Russia

Hardware:1x PC OS Windows 7, 1x Server, 2x Web client Control stations: ICPDAS PET7052
Implementation:RSI SOFT s.r.o. www.rsi-soft.cz
Date of commission:2013

Visualization of free-time activity building technologies. Small water powerplant, heating, electricity and HVE - Kalikovský Mlýn s.r.o, Czech republic

Hardware:1x PC OS Windows XP, 1x WEB client Control stations: AMiT Amap99, 2x Amiris99, ART267A, Amini2D, Amini2, 6x Amini-E
Implementation:Miroslav Legutko www.legutko.cz
Date of commission:2013

A-RCMS monitor - status checking of monitoring devices - AČR, Czech republic

Hardware:1x PC OS Windows 7, 1x Server, 2x Web client Control stations: SNMP, WMI, ICMP protocol
Implementation:A-KOMPLEX a.s. www.akomplex.eu
Date of commission:2012

Replacemet of steam heating by hot water heating - TDK, 35 heat exchange stations, 150 meters Dvůr Králové, Czech republic

Hardware:PC Server Control stations: 35x SAIA PD2M150, Burgess
Implementation:MARTIA a.s. www.martia.cz
Date of commission:2012

Reconstruction of heatplant control centre - Poříčí powerplant Trutnov - Poříčí, Czech republic

Hardware:PC Server Control stations: Sauter, iRSM, SAIA, Schneider
Implementation:MARTIA a.s. www.martia.cz
Date of commission:2012

Mělník 1 powerplant terminal, Czech republic

Hardware:2x PC + 2x PC, Control stations:ZAT
Implementation:OSC a.s. www.osc.cz
Date of commission:2012

Terminal for Prostějov heating plant, Czech republic

Hardware:2x PC + 2x PC, Control stations:METSO
Implementation:OSC a.s. www.osc.cz
Date of commission:2012

Terminal of new ČEZ gas/steam cycle in Počerady, Czech republic

Hardware:2x PC + 2x PC, Control stations:Simatic
Implementation:OSC a.s. www.osc.cz
Date of commission:2012

Visualization and remote control of a heat exchanger network, Univerzita J. E. Purkyně, Czech republic

Hardware:1x PC (Win), Control stations:AMiT
Implementation:Ulimex, s.r.o., www.ulimex.cz
Date of commission:2012

Heating and cooling system (condensation boilers, chiller and heat pump), 2xAC ... Y Soft Corporation a.s. - Brno, Czech republic

Hardware:PC OS Windows Control stations: AMiT ADIS2W, 40x AMR-FCT, AMAP99S, 10xDMxxx, M-Bus, SMS
Implementation:Libor Krutiš – elektro www.lk-elektro.cz
Date of commission:2012

Central heating system in Ruzomberok CZT Ružomberok, s.r.o., Slovakia

Hardware:1x PC OS Windows XP Control stations: 163x Simatic Climatix POL687.xx, 313x měřič tepla Landis+Gyr UH50
Implementation:MARTIA a.s. www.martia.cz
Date of commission:2012

Monitoring and visualisation: Heating pant data collection and archiving - Actherm Chomutov, Czech republic

Hardware:12x PC, MS SQL Server Control stations:
Implementation:MICROSYS, spol. s r.o.
Date of commission:2012

Extension of visualisation application monitoring rolling mill in ArcelorMittal Ostrava a.s. - Arcelor Mittal Ostrava, Czech republic

Hardware:1x PC, 4x Web client Control stations: SAIA
Implementation:MICROSYS, spol. s r.o.
Date of commission:2012

Monitoring and control of heating sources in the public transport system company of the city of BRNO - Husovice Brno, Czech republic

Hardware:2x PC Control stations: 2x Teco Foxtrot, INMAT, ETA hlavice
Implementation:MICROSYS, spol. s r.o.
Date of commission:2012

Measurement and evaluation of electricity and gas consumption for new regeneration boiler and turbine - Biocel Paskov, Czech republic

Hardware:3x PC, MS SQL Server Control stations: Simatic S7-315
Implementation:MICROSYS, spol. s r.o.
Date of commission:2012

Automated reading and evaluation of heat consumption - Dalkia Poprad, Slovakia

Hardware:OS Windows Server Control stations: 630x Danfoss INFOCAL-5, Kamstrup MULTICAL, Calmex
Implementation:MICROSYS, spol. s r.o.
Date of commission:2012

Visualization and evaluation of press technological data - Ostrava, Czech republic

Hardware:OS Windows Server Control stations: Simatic S7-400
Implementation:MICROSYS, spol. s r.o.
Date of commission:2012

Measurement of energy consumption Tubex Slovakia, s.r.o. - Žarnovica, Slovakia

Hardware:OS Windows Server 2008 R2, MS SQL server 2008 Control stations: Simatic S7-1200, Multielektromer BFM136, Schrack NA96
Implementation:GonSoft s.r.o. www.gonsoft.sk
Date of commission:2012

Mobile device for regeneration of transformer oil Reoil 5000-9-3 – Siemens AG TLM - Nurnberg, Germany

Hardware:Deltalogic S7 OPC server, toughbook Panasonic CF-53AA Control stations: Simatic S7-300, CPU 315-2PN/DP
Implementation:GonSoft s.r.o. www.gonsoft.sk
Date of commission:2012

Mobile device for regeneration of transformer oil Reoil 5000-9-2 – Siemens AG TLM - Nurnberg, Germany

Hardware:Deltalogic S7 OPC server, toughbook Panasonic CF-53AA Control stations: Simatic S7-300, CPU 315-2PN/DP
Implementation:GonSoft s.r.o. www.gonsoft.sk
Date of commission:2012

Waste incinerator plant - process visualization, parametrization, malfunction reporting, Plzeň, Czech republic

Hardware:1x PC, Control stations:1x Simatic S7-300
Implementation:Ing.František ŽÁK
Date of commission:2012

Lock assembly automated machine, Nýřany, Czech republic

Hardware:1x PC, Control stations:1x Simatic S7-300
Implementation:Ing.František ŽÁK
Date of commission:2012

Automated strainer assembly DAT, Attendorn, Germany

Hardware:1x PC, Control stations:1x Simatic S7-300
Implementation:Ing.František ŽÁK
Date of commission:2012

Monitoring of salt water aquarium, Czech republic

Hardware:1x NB Control stations:PLC ABB AC500eCO
Implementation:Jan Kunrt
Date of commission:2011

Monitoring of manufacturing facility heating system, Aisan Industry Czech, Louny, Czech republic

Hardware:1x PC (Win), Control stations:AMiT, MP-BUS 32x Belimo
Implementation:Ulimex, s.r.o., www.ulimex.cz
Date of commission:2011

Control of air conditioning units of the printing machine facility, Severotisk, Czech republic

Hardware:1x PC (Win), Control stations:AMiT
Implementation:Ulimex, s.r.o., www.ulimex.cz
Date of commission:2011

The central dispatching of heating system ETI Sokolov - Tisová, Czech republic

Hardware:1x PC Control stations:5x Schneider Electric M340
Implementation:ZPA-RP, a.s. www.zpa-rp.cz
Date of commission:2011

The central dispatching of heating system ETI Sokolov - Tisová, Czech republic

Hardware:1x PC Control stations:5x Schneider Electric M340
Implementation:ZPA-RP, a.s. www.zpa-rp.cz
Date of commission:2011

Parametrization and monitoring of pouring machines - Stará Voda, Czech republic

Hardware:1x PC Control stations:Schneider Electric M340 12xAI, 128xDI, 128xDO
Implementation:ZPA-RP, a.s. www.zpa-rp.cz
Date of commission:2011

Planning sytem of heat and electricity production of the Actherm heating plant, Czech republic

Hardware:12x PC, MS SQL server, Control stations:
Implementation:MICROSYS, spol. s r.o.
Date of commission:2011

Pilot application for machune vibration monitoring, Czech republic

Hardware:1x PC, 2x Web client, MS SQL server, Control stations:
Implementation:MICROSYS, spol. s r.o., Dif s.r.o.
Date of commission:2011

Supervisory centre of energy consumption in Arcelor Mittal tube production plant, Czech republic

Hardware:1x PC, 2x Web client, MS SQL server, Control stations:7x PLC Simatic S7-1200
Implementation:MICROSYS, spol. s r.o., Siemens s.r.o.
Date of commission:2011

The basin of Vltava monitoring system, Czech republic

Hardware:3x PC, MS SQL server, Control stations:
Implementation:MICROSYS, spol. s r.o., Argo Automatizace
Date of commission:2011

Monitoring and control of heating sources in the public transport system company of the city of BRNO - Husovice Brno, Czech republic

Hardware:2x PC, Control stations:PLC Teco Foxtrot, INMAT
Implementation:MICROSYS, spol. s r.o.
Date of commission:2011

Visualization of household heating with Timpex Hanušovice fireplaces, Czech republic

Hardware:1x PC, Control stations:PLC Mires
Implementation:MICROSYS, spol. s r.o., Timpex s.r.o.
Date of commission:2011

Visualization of heating process and consumption evaluation for 156 household transition stations in Kašperské hory, Czech republic

Hardware:1x PC, Control stations:140x Sontex, Kamstrup
Implementation:MICROSYS, spol. s r.o., Kappenberger+Braun
Date of commission:2011

Visualization of emergency fire system in tunnels - pilot application, Czech republic

Hardware:1xIPC Beckhoff (Win XP embeeded), Control stations:
Implementation:MICROSYS, spol. s r.o., KPM CONSULT, a.s.
Date of commission:2011

Visualization of 5 conveyor belts in the technical secondary school laboratory, Czech republic

Hardware:5x PC, Control stations: 5xPLC Unitronics
Implementation:MICROSYS, spol. s r.o.
Date of commission:2011

Security and fire system in Žďár nad Sázavou - Control of SFS, Czech republic

Hardware:Panel PC PMP7170NAC (Finecom) Control stations:PLC Simatic S7-300
Implementation:Regulační technika s.r.o. www.regulujeme.cz
Date of commission:2011

The schooling centre of energy preservation of Intoza s.r.o., Ostrava - Control of HVAC, monitoring of heat pump, Czech republic

Hardware:PC JetBox 8150 (Korenix) Control stations:PLC AMiT ANiNi 4DS
Implementation:Regulační technika s.r.o. www.regulujeme.cz
Date of commission:2011

PPC Malženice power station terminal - E.ON. Elektrárne s.r.o., Slovakia

Hardware:4x PC (Win XP) Control stations:
Implementation:OSC, a.s. www.osc.cz
Date of commission:2011

Car roof assembly automated machine, Přeštice, Czech republic

Hardware:1x PC, Control stations:1x Simatic S7-300
Implementation:Ing.František ŽÁK
Date of commission:2011

SOŠ Prievidza - Condensation heating system, Slovakia

Hardware:1x PC (Win XP) Control stations:CLIMATIX POL638.xx (Siemens)
Implementation:BYTAS, s.r.o www.bytas.sk
Date of commission:2010

SOŠ Handlová - Condensation heating system, Slovakia

Hardware:1x PC (Win XP) Control stations:CLIMATIX POL638.xx (Siemens)
Implementation:BYTAS, s.r.o www.bytas.sk
Date of commission:2010

Barcode test, Czech republic

Hardware:1x PC (OS Windows) Control stations:RS232
Implementation:CTS Corporation www.ctscorp.cz
Date of commission:2010

Mobile device for regeneration of transformer oil Reoil 5000-12-1 – Siemens AG TLM - Nurnberg, Germany

Hardware:Deltalogic S7 OPC server, HP ProBook 4710s Control stations: Simatic S7-300, CPU 315-2PN/DP
Implementation:GonSoft s.r.o. www.gonsoft.sk
Date of commission:2010

Controling the test course of the flowmeters - Pražská teplárenská a.s., Czech republic

Hardware:1x OS (PC, OS Windows XP Professional), SQL server Control stations:1x PLC Simatic S7-317(TCP/IP), Softnet OPC server
Brief application description: Controling application of the test course of flowmeters. Controlling the technology, managing the measurement device catalogue in SQL database, computing the measured values, archiving the data into SQL, procesing the measurement protocols. Communication with the devices via the serial link.
Implementation:MPC System, společnost s r.o. www.mpc.cz
Date of commission:2010

Measurement and evaluation of electricity and gas consumption - Biocel Paskov a.s., Czech republic

Hardware:3x PC, MS SQL Server, Control stations:Simatic S7-317, AMiT Amini
Implementation:MICROSYS, spol. s r.o.
Date of commission:2010

>Visualization and regualtion of exchange stations in the public transport system company of the city of BRNO, Czech republic

Hardware:1x PC, Control stations:Teco Foxtrot
Implementation:MICROSYS, spol. s r.o., Zamat s.r.o.
Date of commission:2010

Measurement and evaluation of quality of pulp production plant - Biocel Paskov a.s., Czech republic

Hardware:10x PC, Oracle, Control stations:ORAM
Implementation:MICROSYS, spol. s r.o.
Date of commission:2010

Monitoring of data from 9 water schemes on the Morava river, Czech republic

Hardware:3x PC, MS SQL server, Control stations:9x AMiT
Implementation:MICROSYS, spol. s r.o., Argo Automatizace
Date of commission:2010

The Trenčín university - Rectorate - Condensation heating system, Slovakia

Hardware:1x PC (Win XP) Control stations:CLIMATIX POL638.xx (Siemens)
Implementation:BYTAS, s.r.o www.bytas.sk
Date of commission:2010

PROMOTIC - voice operated light control, Czech republic

Hardware:1x OS (PC, OS Windows XP Professional), OPC server, ODBC driver, MySQL Control stations:1x PCI6221, 1x CB-68LP, RAS - 0515, panel PT 009 + NIKOBUS
Brief application description:PROMOTIC - voice operated light control
Implementation:VŠB-TU Ostrava, FEI, katedra 452 www.fei.vsb.cz
Date of commission:2010

Automated strainer assembly DV, Žebrák, Czech republic

Hardware:1x PC, Control stations:1x Moeller PS4
Implementation:Ing.František ŽÁK
Date of commission:2010

Car roof assembly automated machine, Přeštice, Czech republic

Hardware:1x PC, Control stations:1x Simatic S7-300
Implementation:Ing.František ŽÁK
Date of commission:2010

Control of exchange station RS2 - Sokolov, Czech republic

Hardware:1x PC Control stations:Schneider Electric M340 16xAI, 4xAO, 64xDI, 64xDO
Implementation:ZPA-RP, a.s. www.zpa-rp.cz
Date of commission:2009

Control of counter pressure turbine and generator MV550G - 5,5MVA Burgas, Bulgaria

Hardware:1x PC Control stations:Simatic S7-300, 48xAI, 4xAO, 64xDI, 32xDO
Implementation:ZPA-RP, a.s. www.zpa-rp.cz
Date of commission:2009

>Monitoring and regulation of tram depot heating system in the public transport system company of the city of BRNO, Czech republic

Hardware:2x PC, Control stations:2x PLC Teco Foxtrot
Implementation:MICROSYS, spol. s r.o.
Date of commission:2009

Measurement and regulation of the dust air pollution in the city of Ostrava, Czech republic

Hardware:2x IPC Midam, Control stations:2x DustTrak
Implementation:MICROSYS, spol. s r.o., ECM ECO monitoring s.r.o.
Date of commission:2009

The Trenčín university FSEV - Condensation heating system, Slovakia

Hardware:1x PC (Win XP) Control stations:SAPHIR ACX32 (Siemens)
Implementation:BYTAS, s.r.o www.bytas.sk
Date of commission:2009

Small hydropower plan in Nymburk, Czech republic

Hardware:1x PC Elvac Control stations:2370kVA, 4x turbína kaplan, 1x francis, 6xPLC AC500
Implementation:Ingea s r.o. www.ingea.cz
Date of commission:2009

Small hydropower plan in Kníničky, Czech republic

Hardware:1x PC Elvac Control stations:3600kVA, 1x turbína kaplan, PLC ABB, AC500
Implementation:Ingea s r.o. www.ingea.cz
Date of commission:2009

Energy consumption control system of Chart Ferox, a.s., Czech republic

Hardware:1x PC WinXPControl stations:AMiT (ADIS, ART 4000, APT 3100, AMINI, V/V, DM modules)
Implementation:Chart Ferox, a.s. www.chart-ferox.com
Date of commission:2009

Control of mineral wool insulation plate production line, dome furnace, Belarus

Hardware:3x PC (Win XP) Control stations:4x Simatic S7-300
Implementation:BSW, spol. s r.o. www.bsw.cz
Date of commission:2009

Complete control and visualization of experimental technological line for fluoride reprocessing of the nuclear fuel , Czech republic

Hardware:1x PC (Win XP) Control stations:1x SAIA PCD2
Implementation:ÚJV Řež a.s. www.ujv.cz
Date of commission:2009

Visualization of experimental laboratory loops with molten fluoride salts , Czech republic

Hardware:1x PC (Win XP) Control stations:1x SAIA PCD3
Implementation:ÚJV Řež a.s. www.ujv.cz
Date of commission:2009

REZA system vizualization in Hunagary, Hungary

Hardware:1x PC (Win) Control stations:REZA (modul EOV)
Implementation:OHL ŽS a.s. www.ohlzs.cz
Date of commission:2009

Malt processing control and monitoring - Sladovna Trnava, Slovakia

Hardware:1x PC (Win) Control stations:2x B&R X20CP1485, 1x B&R 4XP00021, Pointek CLS 100PPS, ACOPOS inverter P84, PowerPanel PP45
Implementation:Agrovos s.r.o. www.agrovos.sk
Date of commission:2009

Emission monitoring, Teplárna Přerov, Czech republic

Hardware:1x PC (Win XP), MS SQL server Control stations:2x datalogger, TDC Honeywell
Implementation:MICROSYS, spol. s r.o., ECM ECO Monitoring, s.r.o.
Date of commission:2009

Dispatching: Data vizualization and a power prediction model for new turbine - Actherm Chomutov, Czech republic

Hardware:1x PC (Win 2003 Server), 10x webClient, MS SQL server
Implementation:MICROSYS, spol. s r.o.
Date of commission:2009

A complete control of the heating and water supply - Lázně Moravská Ostrava (SAREZA), Czech republic

Hardware:1 x PC (OS Windows XP) Control stations: 18x AMiT (3x Amap99 + 3x APT130, Amiris99 + APT130, 11x ART4000, 2x APT3000, APT3100)
Implementation:MKSoft www.mksoft.cz
Date of commission:2009

The measurement and regulation reconstruction - the central treatment station - Levické mliekárne a.s. Levice, Slovakia

Hardware:1 x PC (OS Windows XP), OPC server Control stations: VIPA SPEED7 300S (CPU313SC)
Implementation:GonSoft s.r.o. www.gonsoft.sk
Date of commission:2009

Mobile device for regeneration of transformer oil Reoil 5000S - RWE Rhein-Ruhr Netzservice GmbH - Wesel, Germany

Hardware:Deltalogic S7 OPC server, HP ProBook 4710s Control stations: Simatic S7-300, ACCON Netlink S7
Implementation:GonSoft s.r.o. www.gonsoft.sk
Date of commission:2009

Computing the OEE, collecting the data from 15 stations - CTS Czech Republic, s.r.o., Czech republic

Hardware:1 x PC (OS Windows XP) - 2x Monitor, OPC Control stations: Allen-Bradley MicroLogix 1100, PLC Allen-Bradley SLC 500
Implementation:CTS Czech Republic, s.r.o. ctshome.ctscorp.com
Date of commission:2009

Monitoring the hybrid coal steam boiler - Klatovská teplárna, Czech republic

Hardware:1x PC (Win XP), Control stations:1xPLC Schneider Premium, OPC
Implementation:K&H KINETIC a.s. www.kh-kinetic.cz
Date of commission:2009

Monitoring the chemical water treatment - Klatovská teplárna, Czech republic

Hardware:1x PC (Win XP), Control stations:1xPLC Schneider Unity, 2x Micra, 1x M340, OPC, ADAM
Implementation:K&H KINETIC a.s. www.kh-kinetic.cz
Date of commission:2009

Dispatching: Paint shops and abrasive cleaning units - Medlánky, DPMB a.s, Czech republic

Hardware:2x PC (Win XP), Control stations:2x Teco
Implementation:MICROSYS, spol. s r.o., ZAMAT spol. s r.o.
Date of commission:2009

Emission monitoring powerplant boiler, Muridke, Pakistan

Hardware:1x PC (Win XP), Control stations:2x Simatic S7-300
Implementation:MICROSYS, spol. s r.o., RMT s.r.o
Date of commission:2009

Dispatching: Monitoring and data management of the cartoning line - Biocel Paskov a.s., Czech republic

Hardware:1x PC (Win 2003 Server), 20x webClient Control stations: Simatic S7-300
Implementation:MICROSYS, spol. s r.o.
Date of commission:2009

Monitoring of forging press, Plzeň, Czech republic

Hardware:1x PC, Control stations: Simatic S7-300
Implementation:Ing.František ŽÁK
Date of commission:2009

Automated strainer assembly CRD, Žebrák, Czech republic

Hardware:1x PC, Control stations:1x Moeller PS4
Implementation:Ing.František ŽÁK
Date of commission:2009

Automated strainer assembly G9T, Žebrák, Czech republic

Hardware:1x PC, Control stations:1x Moeller PS4
Implementation:Ing.František ŽÁK
Date of commission:2009

Control of 6 drinking water filters, Water chemistry processing plant Litvínov – Bílý Potok, Czech republic

Hardware:1x PC (Win), Control stations:AMiT
Implementation:ERVIS s.r.o. www.ervis.cz
Date of commission:2008

ČOV Jirkov Waste water treatment plant, Czech republic

Hardware:1x PC (Win XP), Control stations:7xPLC Schneider Premio, Twido, OPC
Implementation:K&H KINETIC a.s. www.kh-kinetic.cz
Date of commission:2008

ČOV Rakovník Waste water treatment plant - sediment systems, boiler plant and gas storage engine room, Czech republic

Hardware:1x PC (Win XP), Control stations:2xPLC SAIA PCD2, OPC server MERZ
Implementation:K&H KINETIC a.s. www.kh-kinetic.cz
Date of commission:2008

Biogas station - Ladzany, Hontianské Moravce, Hurbanovo, Slovakia

Hardware:3x PC (Win XP), Control stations:3xPLC Schneider M340 (Twido)
Implementation:K&H KINETIC a.s. www.kh-kinetic.cz
Date of commission:2008

Biogas station - Třeboň, Czech republic

Hardware:1x PC (Win XP), Control stations:1xPLC Schneider M340 (Twido)
Implementation:K&H KINETIC a.s. www.kh-kinetic.cz
Date of commission:2008

EURO currency warehouse register system Národná banka Slovensko - Bratislava, Nové Zámky, Trenčín, Žilina, Lučenec, Poprad a Humenné, Slovakia

Hardware:7x PC (Win XP), Control stations:5x Mitsubishi
Implementation:MICROSYS, spol. s r.o.
Date of commission:2008

Dispatching: main heat exchange station - Medlánky, DPMB a.s, Czech republic

Hardware:2x PC (Win XP), Control stations:2x Teco
Implementation:MICROSYS, spol. s r.o., ZAMAT spol. s r.o.
Date of commission:2008

Emission monitoring gas-steam turbines, powerplant Bucurest, Romania

Hardware:1x PC (Win XP), Control stations:1x datalogger AMiT AMiNi 2D with I/O module
Implementation:MICROSYS, spol. s r.o., RMT s.r.o
Date of commission:2008

An individual regulation of the room 164x - SOŠ Dopravní, Ostrava, Czech republic

Hardware:1 x PC (OS Windows XP) Control stations: AMiT (5x AMINI2D, AMINI)
Implementation:MKSoft www.mksoft.cz
Date of commission:2008

Operational - energetic management for hotels, Hotel Alwyn, Czech republic

Hardware:1x PC (Win XP), Control stations:24x RS2-B EXAKT, 2x AMiTAMINI2D
Implementation:EXAKT spol. s r.o. www.exakt.pb.cz
Date of commission:2008

Upgrade of the energetic dispatching in the SO33 area, Kovohutě Příbram nástupnická a.s., Czech republic

Hardware:1x PC (Win XP), Control stations:EMS.4 1x -Digicontrol
Implementation:EXAKT spol. s r.o. www.exakt.pb.cz
Date of commission:2008

Operational - energetic management for hotels, Vojenská lázeňská léčebna Balnoosanatorium Kijev, Ukraine

Hardware:1x PC (Win 2000), Control stations:21x RS2-B EXAKT
Implementation:EXAKT spol. s r.o. www.exakt.pb.cz
Date of commission:2008

Operational - energetic management for hotels, Wellness Hotel a.s., Czech republic

Hardware:2x PC (Win XP), Control stations:250x RS2-B EXAKT, 4x PCD 1.NT, ECS.3 6x -Digicontrol, 1x AMiTAMINI2D
Implementation:EXAKT spol. s r.o. www.exakt.pb.cz
Date of commission:2008

Energy Snina, a.s., Snina - The energetic utilization of biomass - the control of two fluid biomass boilers and two electric separators monitoring., Slovakia

Hardware:2x PC (WinXP), Control stations:2x PLC Schneider-Electric Premium
Implementation:Martia a.s. www.martia.cz
Date of commission:2008

Control of technological processes of the after-harvest lines, Vávrovice, Czech republic

Hardware:1x PC (WinXP), Control stations:1x Allex 110/80 I/O, RoutProF
Implementation:Zemědělské družstvo "Hraničář" se sídlem v Loděnici www.zdhranicar.cz
Date of commission:2008

Regeneration-filtering mobile device for transformer oil, Ekofluid s.r.o. Santovka, Slovakia

Hardware:1x PC (Win XP), Control stations:1x Simatic S7-200
Implementation:GonSoft s.r.o. www.gonsoft.sk
Date of commission:2008

Ecological regeneration of transformer oil FLUIDEX R5000-RMB, SEPS a.s. Bratislava, Slovakia

Hardware:1x PC (Win XP), Deltalogic S7 OPC server, Control stations:1x Simatic S7-300
Implementation:GonSoft s.r.o. www.gonsoft.sk
Date of commission:2008

Ecological regeneration of transformer oil REOIL 4000S, LATVENERGO Riga - Lotyšsko, Republic of Latvia

Hardware:1x Siemens OPC server, Control stations:1x Simatic S7-200
Implementation:GonSoft s.r.o. www.gonsoft.sk
Date of commission:2008

Heat meters data collection, SAV Bratislava, Slovakia

Hardware:1x PC (WinXP), Control stations: 1x MULTICAL Master Kamstrup, 37x MULTICAL Slave Kamstrup 601 1x MOXA Serial Device Server NPort 5150, 2x Onesoft Maxtronic 05D, 1x Simatic S7-400, 16x Simatic S7-200
Implementation:GonSoft s.r.o. www.gonsoft.sk
Date of commission:2008

Sever plus, Litvínov Monitoring of 5 terminal delivery stations (central heating system), trends, entering operational data, data storage, Czech republic

Hardware:1x PC (Win XP), Control stations:5x PLC TWIDO - Schneider-Electric, komunikace Modbus radiomodem Conel CDA 70
Implementation:ESI s.r.o. www.esi.cz
Date of commission:2008

Mlékárna Klatovy a.s. Monitoring and entering production prescriptions for 6 cheese curd makers. Production data atrchive., Czech republic

Hardware:1x PC (Win XP), Control stations:6x PLC TSX 37 Micro - Schneider-Electric, komunikace FIP
Implementation:ESI s.r.o. www.esi.cz
Date of commission:2008

Dopravní podnik hl. m. Prahy, a.s. City public transport converter station - Prague Radlice, Czech republic

Hardware:1x PC (Win XP), Control stations:10x CT05, 1x CT02, 1x CU32
Implementation:Microsys Brno, s.r.o. www.microsysbrno.cz
Date of commission:2008

Dopravní podnik města Brna. a.s. City public transport converter station - Brno Spálená, Czech republic

Hardware:1x PC (Win XP), Control stations:8x CT05, 1x CT02, 1x CU32
Implementation:Microsys Brno, s.r.o. www.microsysbrno.cz
Date of commission:2008

Dopravní podnik města Brna. a.s. City public transport converter station - Brno Modřice, Czech republic

Hardware:1x PC (Win XP), Control stations:6x CT05, 1x CT02, 1x CU32
Implementation:Microsys Brno, s.r.o. www.microsysbrno.cz
Date of commission:2008

IFM Group, Brno Monitoring and control gas boiler plant, automated heating for offices and flats, garage monitoring and air conditioning., Czech republic

Hardware:1x PC (Win XP), Control stations:2x PLC AMiT, 1x AMAP99, 1x AMiRiS99 (RS232)
Implementation:RTP spol. s r.o. www.rtp.cz
Date of commission:2008

ČOV Kravaře Waste water treatment plant, Czech republic

Hardware:1x PC (Win XP), Control stations:PLC AMiT, 1x MEST110 (RS232)
Implementation:RTP spol. s r.o. www.rtp.cz
Date of commission:2008

FOSFA a.s. Dosage control system for chemical mixtures used in food-processing., Czech republic

Hardware:1x PC (Win XP), 1x web client, Control stations:PLC Schneider-Electric, Modicon Premium
Implementation:Satec, s.r.o. www.satec.cz
Date of commission:2008

P-D Refractories CZ a.s. Material control and weighting system for chimney insert manufacturing., Czech republic

Hardware:1x PC (Win XP), Control stations:PLC Simatic S7-300
Implementation:Satec, s.r.o. www.satec.cz
Date of commission:2008

STOMIX, s.r.o. Production control system of ready-mixed plasters. Interconnected with Navision information system., Czech republic

Hardware:1x PC (Win XP), 1x web client, Control stations:PLC Schneider-Electric, Modicon Premium, I/O modul ABB
Implementation:Satec, s.r.o. www.satec.cz
Date of commission:2008

Emission monitoring 2 powerplant boilers, Pakistan

Hardware:1x PC (Win XP), Control stations:1x Simatic S7-300
Implementation:MICROSYS, spol. s r.o., RMT s.r.o
Date of commission:2008

Remote temperature reading and thermal nodes monitoring and control system - Zakład Energetyki Cieplnej w Starachowicach Sp. z o.o., Poland

Hardware:1x PC (WinXP), Control stations:Kamstrup: Multical I,II,III, 66C, Compact, Apator LQM, Aquatherm Supercal: 430, 431, 432; Landis&Gyr WSD, Danfoss EEM-C; Praterm Z-Elektronik, Siemens RVD-240/230, Danfoss ECL 200/300; Landis RVP-97
Implementation:Apator Telemetria, Słupsk www.telemetria.eu
Date of commission:2007

Automated strainer assembly TUT3, Žebrák, Czech republic

Hardware:1x PC, Control stations: Beckhoff
Implementation:Ing.František ŽÁK
Date of commission:2008

monitoring of aluminium casting, Děčín, Czech republic

Hardware:1x PC, Control stations: Simatic S7-300
Implementation:Ing.František ŽÁK
Date of commission:2008

Automated strainer assembly CRD, Žebrák, Czech republic

Hardware:1x PC, Control stations: Simatic S7-300
Implementation:Ing.František ŽÁK
Date of commission:2008

Control and monitoring of coal feeding- Plzeňská energetika a.s., Czech republic

Hardware:2x OS (PC DELL Precision 390, OS Windows XP, 2x monitor) Control stations:3x PLC Simatic S7-317(TCP/IP), 4 x I/O Turck (Profibus), Softnet OPC server
Brief application description: Controlling and monitoring the coal feeding of the boilers. Complete control and monitoring of the conveyor belts, checking the coal levels in storage. The login system is based on access cards. The communication between the PC and PLC is done via Ethernet TCP/IP by the Softnet OPC server.
Implementation:MPC System, společnost s r.o. www.mpc.cz
Date of commission:2007

Control and monitoring of coal feeding - Teplárna Tábor a.s., Czech republic

Hardware:1x OS (Panel PC Advantech, OS Windows XP Professional) Control stations:1x PLC GE-Fanuc (Ethernet TCP/IP), GE OPC server.
Brief application description: Control and monitoring of coal-feeding lines for boilers. Complete control and monitoring of line status, supervising the coal levels in containers.
Implementation:MPC System, společnost s r.o. www.mpc.cz
Date of commission:2007

Monitoring and control system of experimental gasifying device (SK), Slovakia

Hardware:1x OS Windows XP Professional), Bernecker&Reiner PVI OPC Control stations:PLC Bernecker&Reiner 1x X20CP1485, 3x X20DO9322, 1x X20DI9371, 4x X20AI4622, 4x X20AO4622, 11x X20AT6402
Implementation:TU Košice web.tuke.sk/uraivp/
Date of commission:2007

Dopravní podnik města Brna. a.s. City public transport converter station - Brno Šlapanice, Czech republic

Hardware:1x PC (Win XP), Control stations:9x CT05, 1x CT02, 1x CU32
Implementation:Microsys Brno, s.r.o. www.microsysbrno.cz
Date of commission:2007

Electric power consumption monitoring system - DURA Kopřivnice, Czech republic

Hardware:1x PC (Win XP), Control stations:1x Simatic S7-300
Implementation:MICROSYS, spol. s r.o.
Date of commission:2007

Water consumption measurement based on indirect load method - ČEZ, a.s. - Elektrárna Mělník, Czech republic

Hardware:1x PC, Control stations:10x elektroměry ENERMET
Implementation:OSC a.s. www.osc.cz
Date of commission:2007

Intranet production info server - water, heat, electricity - ZSNP, a.s. Závod Energetik, Slovakia

Hardware:1x PC (Win XP),
Implementation:ZSNP, a.s.
Date of commission:2007

Coaling - Hexion Specialty Chemicals, a.s., Czech republic

Hardware:1x PC (Win XP), Control stations:OPC Schneider Electric OFS3.31, Schneider-Electric Quantum
Implementation:ZPA-RP, a.s. www.zpa-rp.cz
Date of commission:2007

Monitoring, TC Mach heat pump, complex smart house management - p.Rumla Prague 6, Czech republic

Hardware:1x PC, Control stations:1x SAIA
Implementation:Atria Control, s.r.o. www.atria-control.cz
Date of commission:2007

Monitoring and archiving of operational data in a foundry - Alulit Benešov, Metaz, a.s Týnec n. Sázavou, Czech republic

Hardware:2x PC, Control stations:4x (Benešov) + 6x (Týnec) Mitsubishi, GSM modem
Implementation:Atria Control, s.r.o. www.atria-control.cz
Date of commission:2007

VOC disposal, IACG s.r.o., Czech republic

Hardware:1x PC (Win 2000), Control stations:1x AMiT ADIS
Implementation:EXAKT spol. s r.o. www.exakt.pb.cz
Date of commission:2007

Oxidation catalytic unit, Spolchemie a.s., Czech republic

Hardware:1x PC (Win XP), Control stations:AMiT AMAP99
Implementation:EXAKT spol. s r.o. www.exakt.pb.cz
Date of commission:2007

Operational - energetic management for hotels, Hotel Ludmila, Czech republic

Hardware:1x PC (Win 2003 Server), Control stations:30x RS2-B EXAKT
Implementation:EXAKT spol. s r.o. www.exakt.pb.cz
Date of commission:2007

Operational - energetic management for hotels, Vojenská lázeńská léčebna Teplice, Czech republic

Hardware:1x PC (Win XP), Control stations:12x RS2-B EXAKT
Implementation:EXAKT spol. s r.o. www.exakt.pb.cz
Date of commission:2007

Operational - energetic management for hotels, Hotel Chvalská Tvrz, Czech republic

Hardware:1x PC (Win XP), Control stations:26x RS2-B EXAKT, 26x Basicom, 2x AMiTAMINI2D
Implementation:EXAKT spol. s r.o. www.exakt.pb.cz
Date of commission:2007

Mineral water sources data mining and monitoring system - Kúpele Bardejov, Slovakia

Hardware:1x PC, Control stations:1x Mitsubishi Alfa, GSM
Implementation:DELTA plus s.r.o. www.deltaplus.sk
Date of commission:2007

Mineral water sources data mining and monitoring system - Kúpele Lúčky, Slovakia

Hardware:1x PC, Control stations:A/D a DI modules ICP DAS
Implementation:DELTA plus s.r.o. www.deltaplus.sk
Date of commission:2007

Kolín power station terminal - boiler and turbine production control system, Elektrárna Kolín, a.s., Czech republic

Hardware:1x PC, Control stations:4x ZAT, Schneider Automation, ABB
Implementation:OSC a.s. www.osc.cz
Date of commission:2007

Emission monitoring in 6 objects - Arcelor Mittal a.s. Ostrava, Czech republic

Hardware:1x PC (Win), Control stations:9x datalogger
Implementation:MICROSYS, spol. s r.o., ECM ECO Monitoring, s.r.o.
Date of commission:2007

Dispatching center heat pump plants - Moravský Krumlov, Czech republic

Hardware:1x PC (Win 2003 Server), Control stations:10x AMiT
Implementation:MICROSYS, spol. s r.o., TC Mach
Date of commission:2007

Dispatching center of heat sources - SDC Ostrava, České dráhy a.s., Czech republic

Hardware:2x PC (Win XP), Control stations:6x PLC Teco, 2x AMiT
Implementation:MICROSYS, spol. s r.o.
Date of commission:2007

Dispatching center energetic management and swimming pool technologies control - Slovenské liečebné kúpele Turčianske Teplice, Slovakia

Hardware:1x PC, Control stations:10x Mitsubishi, MULTICAL Kamstrup
Implementation:DELTA plus s.r.o. www.deltaplus.sk
Date of commission:2007

Monitoring of air conditioning and heating system of a building ČNB Ústí n. Labem, Czech republic

Hardware:1x PC, Control stations:3x SAIA PCD3, GSM modem, dálková správa
Implementation:Atria Control, s.r.o. www.atria-control.cz
Date of commission:2007

Expanding the electroenergetics dispatching by cogeneration - OKK OKD a.s., Czech republic

Hardware:2x PC (Win XP), Control stations:5x AMiT AMiNi
Implementation:MICROSYS, spol. s r.o.
Date of commission:2007

Dispatching center of the heating plant management of the Husovice depot - DPMB a.s., Czech republic

Hardware:2x PC (Win XP), Control stations:2x Teco
Implementation:MICROSYS, spol. s r.o.
Date of commission:2007

Monitoring and regulation heating of the central office building - DPMB a.s., Czech republic

Hardware:2x PC (Win XP), Control stations:1x Teco, ETA hlavice
Implementation:MICROSYS, spol. s r.o.
Date of commission:2007

Automated strainer assembly W06B, Žebrák, Czech republic

Hardware:1x PC, Control stations:1x Moeller PS4
Implementation:Ing.František ŽÁK
Date of commission:2007

Automated strainer assembly F4K4, Žebrák, Czech republic

Hardware:1x PC, Control stations: Beckhoff
Implementation:Ing.František ŽÁK
Date of commission:2007

Monitoring of forging press, Dubnica, Slovakia

Hardware:1x PC, Control stations:1x Simatic S7-300
Implementation:Ing.František ŽÁK
Date of commission:2007

Control of stock control, Olpran Olomouc, Czech republic

Hardware:2x PC (Win XP), Control stations:1x Mitsubishi
Implementation:MICROSYS, spol. s r.o., Ing.Miroslav Horák-HOZST
Date of commission:2006 - 2007

Register system of medium of exchange, Slovakia National Bank, branch Poprad, Humenné, Slovakia

Hardware:2x PC (Win XP), Control stations:2x RMC
Implementation:MICROSYS, spol. s r.o.
Date of commission:2006

Monitoring and visualisation, hose diameter evaluation, Goodyear Ostrava s.r.o., Czech republic

Hardware:2x PC (Win XP), Control stations:2x AMiT Amini
Implementation:MICROSYS, spol. s r.o.
Date of commission:2006

Gas stokehold, Dispatching and control system - Bohumín, České dráhy a.s., Czech republic

Hardware:1x PC (Win XP), Control stations:1x Teco 203
Implementation:MICROSYS, spol. s r.o.
Date of commission:2006

Promotic central control system in Povážské Bystrica, Slovakia

Hardware:1x PC (WinXP), Control stations:Mitsubishi
Implementation:ACP AuCOMP s.r.o. www.acp.sk
Date of commission:2006

Monitoring and visualisation: Drier and furnace operation - Wieneberger Týn nad Vltavou, Czech republic

Hardware:2x PC (Win XP), Control stations:2x Simatic S5
Implementation:MICROSYS, spol. s r.o.
Date of commission:2006

Dispatching, 37 heat exchanger stations - Ostrava - Zábřeh, Dalkia a.s., Czech republic

Hardware:1x PC (Win XP), Control stations:37x PLC Saphir
Implementation:MICROSYS, spol. s r.o. + AM technik s.r.o.
Date of commission:2006

Emission monitoring - Biocel Paskov, Czech republic

Hardware:1x PC (Win XP), Control stations:3x datalogger
Implementation:MICROSYS, spol. s r.o. + ECM ECO Monitoring, s.r.o.
Date of commission:1996, 2006

Monitoring and visualisation: Heating plant operation data - Actherm Chomutov, Czech republic

Hardware:1x PC (Win 2003 Server) + 10 client PC, MS SQL server
Implementation:MICROSYS, spol. s r.o.
Date of commission:2006

Operational - energetic management for hotels, Vojenská lázeňská zotavovna Malý Šišák, Czech republic

Hardware:1x PC (Win XP), Control stations:2x AMiT AMINI E
Implementation:EXAKT spol. s r.o. www.exakt.pb.cz
Date of commission:2006

Operational - energetic management for hotels, Grandhotel Zlatý lev a.s., Czech republic

Hardware:1x PC (Win XP), Control stations:136x RS2-B EXAKT
Implementation:EXAKT spol. s r.o. www.exakt.pb.cz
Date of commission:2006

Heat meters, water meters, gas meters and electricity meters data collection, Dalkia a.s. Poprad, Slovakia

Hardware:1x PC (Win 98), Control stations:5x Calmex, 2x vodoměr, 1x elektroměr, 1x plynoměr ECS
Implementation:GonSoft s.r.o. www.gonsoft.sk
Date of commission:2006

Dopravní podnik hl. m. Prahy, a.s. City public transport converter station - Prague Holešovice, Czech republic

Hardware:1x PC (Win XP), Control stations:13x CT05, 1x CT02, 1x CU32
Implementation:Microsys Brno, s.r.o. www.microsysbrno.cz
Date of commission:2006

Dopravní podnik hl. m. Prahy, a.s. City public transport converter station - Prague Ohrada, Czech republic

Hardware:1x PC (Win 2000), Control stations:12x CT05, 1x CT02
Implementation:Microsys Brno, s.r.o. www.microsysbrno.cz
Date of commission:2006

Clear river Bečva: Monitoring and visualisation - Dispatching, Waste water treatment plant Valašské Meziřičí, Czech republic

Hardware:3x PC (WinXP), Control stations: 36x Allen-Bradley SLC500, Server RSLinx, OPC
Implementation:Microsys Brno, s.r.o. www.microsysbrno.cz
Date of commission:2006

Clear river Bečva: Monitoring and visualisation - Dispatching, Waste water treatment plant Zubří, Czech republic

Hardware:3x PC (WinXP), Control stations: 8x Allen-Bradley SLC500, Server RSLinx, OPC
Implementation:Microsys Brno, s.r.o. www.microsysbrno.cz
Date of commission:2006

Clear river Bečva: Monitoring and visualisation - Dispatching, Waste water treatment plant Vsetín, Czech republic

Hardware:3x PC (WinXP), Control stations:8x Allen-Bradley CompactLogix
Implementation:Microsys Brno, s.r.o. www.microsysbrno.cz
Date of commission:2006

Monitoring and visualisation: Enterprise data - Model Obaly a.s., Bilgoraj, Poland

Hardware:5x PC OS Windows, MS SQL
Implementation:MICROSYS, spol. s r.o.
Date of commission:2006

Monitoring and visualisation: Enterprise data - Model Obaly a.s., Nymburk, Czech republic

Hardware:7x PC OS Windows, MS SQL
Implementation:MICROSYS, spol. s r.o.
Date of commission:2006

Emission monitoring for mobile measurement car - ČIŽP Prague, Czech republic

Hardware:1x PC (Win XP), Control stations:1x datalogger
Implementation:MICROSYS, spol. s r.o. + ECM ECO Monitoring, s.r.o.
Date of commission:2006

Control system: 2x TARPO press - Autopal Nový Jičín, Czech republic

Hardware:-, Control stations:2x Simatic C7-613
Implementation:MICROSYS, spol. s r.o. + Tarpo s.r.o.
Date of commission:2006

Reduction and heat exchange station operating control centre - Ostrava - Fifejdy, Dalkia a.s., Czech republic

Hardware:1x PC (Win XP), Control stations:1x Simatic
Implementation:MICROSYS, spol. s r.o. + Siemens Ostrava, s.r.o.
Date of commission:2006

Cetral exchange station - Hexion Specialty Chemicals, a.s., Czech republic

Hardware:1x PC (WinXP), OPC Control stations:Schneider-Electric Premium
Implementation:ZPA-RP, a.s.
Date of commission:2006

Dispatching: Central car wash room - Medlánky, DPMB a.s., Czech republic

Hardware:1x PC (Win XP), Control stations:3x Teco
Implementation:MICROSYS, spol. s r.o.
Date of commission:2006

Measuring of the energy consumption - Teplice, United Energy, Czech republic

Hardware:1x PC (WinXP), Control stations:12x MULTICAL
Implementation:SEA a.s. Příbram www.seaas.cz
Date of commission:2006

Evaluation SW for test pump line, Výrobna kyslíka v závode Trnava, Slovakia

Hardware:1x PC (WinXP), Control stations:Mitsubishi FX
Implementation:DELTA plus s.r.o. www.deltaplus.sk
Date of commission:2006

Automated strainer assembly Nissan, Šanghaj, China

Hardware:1x PC, Control stations:1x Moeller PS4
Implementation:Ing.František ŽÁK
Date of commission:2006

Monitoring of metallurgical plant, Plzeň, Czech republic

Hardware:1x PC, Control stations:1x Simatic S7-300
Implementation:Ing.František ŽÁK
Date of commission:2006

Automated strainer assembly BMW N43, Žebrák, Czech republic

Hardware:1x PC, Control stations: Beckhoff
Implementation:Ing.František ŽÁK
Date of commission:2006

Automated strainer assembly BMW M57, Žebrák, Czech republic

Hardware:1x PC, Control stations: Beckhoff
Implementation:Ing.František ŽÁK
Date of commission:2006

Automated press, Žebrák, Czech republic

Hardware:1x PC, Control stations: Simatic S7-200
Implementation:Ing.František ŽÁK
Date of commission:2006

Monitoring of forging press, Plzeň, Czech republic

Hardware:1x PC, Control stations: Simatic S7-300
Implementation:Ing.František ŽÁK
Date of commission:2006

Register system of medium of exchange, Slovakia National Bank Bratislava, branch Nové Zámky, Trenčín, Žilina, Lučenec, Slovakia

Hardware:5x PC (Win XP), Control stations:5x Mitsubishi
Implementation:MICROSYS, spol. s r.o.
Date of commission:2005

Water processing plant monitoring - ZSNP, a.s. Závod Energetik, Slovakia

Hardware:1x PC (Win XP), Control stations:4x Eko200, Dix
Implementation:ZSNP, a.s.
Date of commission:2005

SMS GSM signal system co-oparating with AirLiquide system, Trnava, Slovakia

Hardware:1x PC (WinXP), Control stations:Modicon, GSM modul TC35 Siemens
Implementation:DELTA plus s.r.o. www.deltaplus.sk
Date of commission:2005

Monitoring and control: heating for buildings - COOP Jednota Prievidza (40x), COOP Jednota Krupina (1x), Slovakia

Hardware:2x PC (WinXP), Control stations:SOFTERM, OMOS, SOFTCONTROL
Implementation:OneSoft s.r.o. Prievidza www.onesoft.sk
Date of commission:2005

Monitoring and control: heating for buildings - Prešov, obvod Sekčov (7x), Slovakia

Hardware:1x PC (WinME), Control stations:SOFTCONTROL, MAXTRONIC, MULTICAL
Implementation:OneSoft s.r.o. Prievidza www.onesoft.sk
Date of commission:2005

Monitoring and control: heating exchange station heating system - OST - 118 Košice, Slovakia

Hardware:1x PC (WinME), Control stations:SOFTCONTROL
Implementation:OneSoft s.r.o. Prievidza www.onesoft.sk
Date of commission:2005

Wood kiln, Monitoring and control, Hungary

Hardware:1x PC (WinME), Control stations:REGULA KS
Implementation:OneSoft s.r.o. Prievidza www.onesoft.sk
Date of commission:2005

Monitoring of distribution point (database, events, failures) - CVS Těchonín, Eurotel ECM Prague, Mafra Prague, Czech republic

Hardware:1x PC, Control stations:Scheider TSX Premium, Modbus, 2x Rotační UPS Caterpillar
Implementation:Atria s.r.o.
Date of commission:2005

Swimming pool (database, events, failures) - Škoda M. Boleslav, Czech republic

Hardware:1x PC, Control stations: SAIA PCD2.M150, Modbus
Implementation:Atria s.r.o.
Date of commission:2005

Bulding monitoring in ministry of Defence (database, events, failures, 1/4h max) - St. Boleslav, Czech republic

Hardware:1x PC, Control stations:Scheider TSX Premium, Modbus
Implementation:Atria s.r.o.
Date of commission:2005

Test automaton - evaluation, archiv and statistics of production data, Mubea s.r.o., Czech republic

Hardware:1x PC, Control stations:Moeller PS4
Implementation:Ing.František ŽÁK
Date of commission:2005

Tube test KI, KII and KII station - WAVIN Ekoplastik s.r.o., Kostelec nad Labem, Czech republic

Hardware:3x PC (WinXP) Control stations:3x Modicon TSX 3721
Implementation:XiNTECO s.r.o. www.xinteco.cz
Date of commission:2005

Dispatching: Biomass stokehold - Kašperské Hory, Czech republic

Hardware:1x PC (Win XP), Control stations:2x PLC Schmidt
Implementation:MICROSYS, spol. s r.o.
Date of commission:2005

Exchanger and stokehold control - Důl 9.květen - Karviná, Czech republic

Hardware:1x PC (WinXP) Control stations:1x SAIA
Implementation:Hradil Antonín - haadex www.cbox.cz/haadex
Date of commission:2005

Test automaton - evaluation, archiv and statistics of production data, Mubea s.r.o., Czech republic

Hardware:1x PC, Control stations:Moeller PS4
Implementation:Ing.František ŽÁK
Date of commission:2005

Monitoring and visualisation: The wine production - Livi Dubňany, Czech republic

Hardware:1x PC (Win XP), Control stations:1x AMiT
Implementation:MICROSYS, spol. s r.o.
Date of commission:2005

Test automaton - evaluation, archiv and statistics of production data, Mubea s.r.o., Czech republic

Hardware:1x PC, Control stations:Moeller PS4
Implementation:Ing.František ŽÁK
Date of commission:2005

Operational data record - press, CPForge a.s., Czech republic

Hardware:1x PC, Control stations:1x Mitsubishi
Implementation:Ing.František ŽÁK
Date of commission:2005

Waste water treatment plant, Energy consumption report nad K2,K3,K4 boiler monitoring - United Energy a.s. divize Teplo, Mimon, Czech republic

Hardware:1x PC (WinXP), Control stations:2x WAGO
Implementation:SEA a.s. Příbram www.seaas.cz
Date of commission:2005

Technology monitoring, operational data record - hop processing line, Chmelařství družstvo Žatec, Czech republic

Hardware:1x PC, Control stations:1x Mitsubishi
Implementation:Ing.František ŽÁK
Date of commission:2005

Peroxides production - Conlac spol. s r.o., Czech republic

Hardware:1x PC (WinXP), OPC Control stations:Simatic S7-300, OPC
Implementation:ZPA-RP, a.s.
Date of commission:2005

Control system: 3x TARPO press - Autopal Nový Jičín, Czech republic

Hardware:, Control stations:3x Simatic C7-613
Implementation:MICROSYS, spol. s r.o. + Tarpo s.r.o.
Date of commission:2005

Measurement and regulation of electricity and gass - Wienerberger Jezernice, Czech republic

Hardware:1x PC (Win XP), Control stations:1x AMiT Amini, Elcor94
Implementation:MICROSYS, spol. s r.o.
Date of commission:2005

Exchanger control - Vítkovice a.s. Stamont, Czech republic

Hardware:1x PC (WinXPP) Control stations:8x AMiT
Implementation:Hradil Antonín - haadex www.cbox.cz/haadex
Date of commission:2005

Measurement and evaluation of the water and gass consumption - DURA Kopřivnice, Czech republic

Hardware:1x PC (Win XP), Control stations:1x AMiT Amini, Elcor94
Implementation:MICROSYS, spol. s r.o.
Date of commission:2005

Emission monitoring - Koksovna Svoboda, Ostrava, Czech republic

Hardware:1x PC, Control stations:3x datalogger
Implementation:MICROSYS, spol. s r.o. + ECM ECO Monitoring, s.r.o.
Date of commission:1996, 2005

Boiler K13 50t/h - RSM Chemacryl, a.s. Sokolov, Czech republic

Hardware:1x PC (WinXP), OPC Control stations:Schneider-Electric Quantum
Implementation:ZPA-RP, a.s.
Date of commission:2005

Test automaton - evaluation, archiv and statistics of production data, Mubea s.r.o., Czech republic

Hardware:1x PC, Control stations:Moeller PS4
Implementation:Ing.František ŽÁK
Date of commission:2005

Boiler K14 50t/h - RSM Chemacryl, a.s. Sokolov, Czech republic

Hardware:1x PC (WinXPP), OPC Control stations:Schneider Electric Quantum
Implementation:ZPA-RP, a.s.
Date of commission:2005

Control of: transportation and storage of barleycorn and malt - Sladovny Soufflet ČR a.s., provoz Kroměříž, Czech republic

Hardware:3x PC (Win2000) + OPC Control stations:2xSimatic S5-135U, 33x Krohne
Implementation:XiNTECO s.r.o. www.xinteco.cz
Date of commission:2005

Emission monitoring - Spalovna FN Hradec Králové, Czech republic

Hardware:1x PC, Control stations:1x datalogger
Implementation:MICROSYS, spol. s r.o. + ECM ECO Monitoring, s.r.o.
Date of commission:2005

Emission monitoring - Koksovna Šverma, Ostrava, Czech republic

Hardware:1x PC, Control stations:2x datalogger
Implementation:MICROSYS, spol. s r.o. + ECM ECO Monitoring, s.r.o.
Date of commission:2005

Exchangers control and town heating, communication by RACOM radio - DALKIA ČR a.s. Frýdek Místek, Czech republic

Hardware:1x PC (WinXP), SQL Control stations:10x AMiT, RACOM
Implementation:Hradil Antonín - haadex www.cbox.cz/haadex
Date of commission:2005

Water chemistry processing plant + Drinking water production - Plzeňská teplárenská a.s., Czech republic

Hardware:2x PC (WinXP), Control stations:17x Schneider-Electric TSX Premium a TSX Micro, Nano, Momentum
Implementation:invelt-elektro, s.r.o. www.invelt.cz
Date of commission:1998 - 2005

Control of: heating and air conditioning of facilities - Aliachem a.s., o.z. Fatra Napajedla, provoz Chropyně, Czech republic

Hardware:1x PC (Win2000), Control stations:8x Landis&Gyr - Unigyr RWP80
Implementation:XiNTECO s.r.o. www.xinteco.cz
Date of commission:2005

Monitoring - Acterm s.r.o. Chomutov, Czech republic

Hardware:1x PC (WinXP), Control stations:70x podstanic RSZ, iRSM, AMiT
Implementation:Martia a.s. www.martia.cz
Date of commission:2005

Head supplement in Kopisty area - Mostecká uhelná a.s., Czech republic

Hardware:1x PC (WinXP), Control stations: 1x Simatic S7 300, 11x Simatic S7 200
Implementation:Martia a.s. www.martia.cz
Date of commission:2005

Upgrade of the MaR system in VS Doly Bilina - Severočeské doly, a.s. Doly Bílina, Czech republic

Hardware:1x PC (WinXP), Control stations: 1x Simatic S7 300, 2x Simatic S7 200
Implementation:Martia a.s. www.martia.cz
Date of commission:2005

Polyester synthetic resin - Spolek pro chemickou a hutní výrobu, a.s., Czech republic

Hardware:1x PC (WinXP), Control stations:ACS
Implementation:Martia a.s. www.martia.cz
Date of commission:2005

Update of dispatcher SW - MUS Uniservis s.r.o., Czech republic

Hardware:2x PC (WinXP), Control stations: 5x RSZ - Sauter, iRSM - Martia a.s.
Implementation:Martia a.s. www.martia.cz
Date of commission:2005

Monitoring and visualisation: Business data in SQL database - Model Obaly a.s, Czech republic

Hardware:10xPC OS Citrix, 5x PC OS Windows, MS SQL
Implementation:MICROSYS, spol. s r.o.
Date of commission:2005

Waste water treatment plant, interest municipality association Nýřany, Tlučná, Vejprnice, Czech republic

Hardware:1x PC (WinXP), Control stations:Modicon TSX Micro
Implementation:SEA a.s. Příbram www.seaas.cz
Date of commission:2005

Emission monitoring for mobile measuring - Třinecké železárny a.s., Czech republic

Hardware:1x PC, Control stations:1x datalogger
Implementation:MICROSYS, spol. s r.o.
Date of commission:2000, 2005

Natatorium heat and mud bath preparation - Lázně Velichovky, Czech republic

Hardware:1x PC (WinXP) Control stations:2x AMiT
Implementation:Hradil Antonín - haadex www.cbox.cz/haadex
Date of commission:2005

Technical gas filling - SIAD Rajhradice u Brna, Czech republic

Hardware:1x PC (WinXP) Control stations:1x Simatic
Implementation:Hradil Antonín - haadex www.cbox.cz/haadex
Date of commission:2005

Dopravní podnik města Brna a.s. City public transport converter station - Brno Osová, Czech republic

Hardware:1x PC (Win 2000), Control stations:8x CT05, 1x CT02, 1x CU32
Implementation:Microsys Brno, s.r.o. www.microsysbrno.cz
Date of commission:2004

Dopravní podnik města Olomouce a.s. City public transport converter station - Olomouc Neředín, Czech republic

Hardware:1x PC (Win 2000), Control stations:6x CT05, 1x CU32
Implementation:Microsys Brno, s.r.o. www.microsysbrno.cz
Date of commission:2004

Dispatching center of heat supplier, KMET a.s. Handlova, Slovakia

Hardware:2x PC (WinXP), Control stations: 126x SAIA, ADOS, AMiT Amiris
Implementation:DELTA plus s.r.o. www.deltaplus.sk
Date of commission:2004

Monitoring system of mineral water sources, TMV a.s. Trenčín, plniareň minerálnych vôd Tr.Mitice, Slovakia

Hardware:2x PC (WinXP), Control stations:8x ICP CON, ComerGon
Implementation:DELTA plus s.r.o. www.deltaplus.sk
Date of commission:2004

Thermal meters data collection and monitoring, ZSNP, a.s. Závod Energetik, Slovakia

Hardware:1x PC (WinXP), Control stations:60x Clamex, MULTICAL, PmInmat66
Implementation:ZSNP, a.s.
Date of commission:2002 - 2004

Waterworks automation - RSM Chemacryl, a.s. Sokolov, Czech republic

Hardware:2x PC (WinXPP), OPC Control stations:Schneider-Electric Quantum
Implementation:ZPA-RP, a.s.
Date of commission:2004

Bearing refrigeration by hydrogen - Nuclear power station MOCHOVCE, Slovakia

Hardware:1x PC (WinXP) Control stations:1x Simatic
Implementation:Hradil Antonín - haadex www.cbox.cz/haadex
Date of commission:2004

Control system: Generator TG2 6MW - RSM Chemacryl, a.s. Sokolov, Czech republic

Hardware:1x PC (WinXP), OPC Control stations:Schneider-Electric Quantum
Implementation:ZPA-RP, a.s.
Date of commission:2004

Waste water treatment plant, Písek, Czech republic

Hardware:1x PC (WinXP), Control stations:3x Modicon Premium, Micro
Implementation:SEA a.s. Příbram www.seaas.cz
Date of commission:2004

Exchange stations, Monitoring and control, Litoměřice, United Energy, Czech republic

Hardware:1x PC (WinXP), Control stations:3x Schneider-Electric TSX Momentum
Implementation:SEA a.s. Příbram www.seaas.cz
Date of commission:2004

Exchange stations, Monitoring and control, Jirkov, United Energy Chomutov, Czech republic

Hardware:1x PC (WinXP), Control stations:8x SEA MPS
Implementation:SEA a.s. Příbram www.seaas.cz
Date of commission:2004

Emission monitoring, incinerator, County hospital Liberec, Czech republic

Hardware:1x PC (WinXP), Control stations:1x AMiT Amini E
Implementation:MICROSYS, spol. s r.o. + RTM
Date of commission:2004

Emission monitoring, incinerator, Megawaste-Ekoterm, Prostějov, Czech republic

Hardware:1x PC (WinXP), Control stations:1x AMiT Amini E
Implementation:MICROSYS, spol. s r.o. + RTM
Date of commission:2004

TEZ Control system extension with GEKO regulation, Slatina, DPMB a.s., Brno, Czech republic

Hardware:, Control stations:Teco TECOreg
Implementation:MICROSYS, spol. s r.o.
Date of commission:2004

Energy monitoring extension by 2 saw measuring, Biocel Paskov a.s., Czech republic

Hardware:3x PC (WinXP), Control stations:AMiT Amini
Implementation:MICROSYS, spol. s r.o.
Date of commission:2004

Dispatching center of the heating plant Zatec, Žatecká teplárenská a.s., Czech republic

Hardware:1x PC (WinXP), 9x COM (MOXA), Control stations: 135x Satchwell (IAC 400, 600), 12x Landis&Gyr PRV 2
Implementation:ESI s.r.o. www.esi.cz
Date of commission:2004

Dispatching center of the heating plant Litomerice, United Energy a.s., Czech republic

Hardware:1x PC (WinXP), 7x COM (MOXA), Control stations:30x Satchwell (IAC 400, 600)
Implementation:ESI s.r.o. www.esi.cz
Date of commission:2004

Heating plant terminal, Dalkia ČR,a.s., heating plant Olomouc, Czech republic

Hardware:1x PC (WinXP), Control stations:1x Simatic S5
Implementation:OSC a.s. www.osc.cz
Date of commission:2004

Control of: Liquid substratum bottler - Aliachem a.s., o.z. Fatra, Napajedla, Czech republic

Hardware:1x PC (WinXP), Control stations:1x SAIA
Implementation:XiNTECO s.r.o. www.xinteco.cz
Date of commission:2004

Fabrication automaton - evaluation, archiv and statistics of production data, Mubea s.r.o., Czech republic

Hardware:1x PC, Control stations:Moeller PS4
Implementation:Ing.František ŽÁK
Date of commission:2004

Waterwork dispatching, trensmission in GSM network, Domažlicko, Czech republic

Hardware:2x PC (WinXP), Control stations:12x SAIA PCD2, Mitsubishi FX1N, FX2N
Implementation:Atria s.r.o.
Date of commission:2004

Emission monitoring LUKOIL, Korobkovsky, Russia

Hardware:3x PC (WinXP), Control stations:20x Teco
Implementation:MICROSYS, spol. s r.o. + ECM ECO Monitoring
Date of commission:2004

Monitoring by technological variables Leadpress and 2 Boilers, Semperflex Optimit Odry, Czech republic

Hardware:5x PC (WinXP), Control stations:3x AMiT Amini E/1M
Implementation:MICROSYS, spol. s r.o.
Date of commission:2004

Dispatching center of the heating plant, Mimoň Ralsko, United Energy a.s., Czech republic

Hardware:1x PC (WinXP), GSM modemy CONEL, Control stations:1x Schneider-Electric TWIDO, MOMENTUM
Implementation:ESI s.r.o. www.esi.cz
Date of commission:2004

Heating plant terminal Usti nad Labem, Teplárny Ústí nad Labem, a.s., Czech republic

Hardware:1x PC (WinXP), Control stations:1x Honeywell HPM
Implementation:OSC a.s. www.osc.cz
Date of commission:2004

Monitoring of selected machines - Brano a.s., člen Brano Group, SBU CS Rakovník, Czech republic

Hardware:1x PC (WinXP), Control stations:1x ADAM 4053
Implementation:Martia a.s. www.martia.cz
Date of commission:2004

Waste water treatment plant: Poděbradka a.s., Poděbrady, Czech republic

Hardware:1x PC (WinXP) + SQL server, Control stations:1x Simatic S7-300
Implementation:Martia a.s. www.martia.cz
Date of commission:2004

Monitoring of dangerous substance leakage - Spolek pro chemickou a hutní výrobu a.s., Ústí nad Labem, Czech republic

Hardware:1x PC (WinXP) + SQL server, Control stations:4x Simatic S7-300
Implementation:Martia a.s. www.martia.cz
Date of commission:2004

Test automaton - evaluation, archiv and statistics of production data, Mubea s.r.o., Czech republic

Hardware:2x PC, Control stations:Moeller XC201
Implementation:Ing.František ŽÁK
Date of commission:2004

Water power station - ZČE,a.s. Černé Jezero, 2,7MW Hracholusky, Czech republic

Hardware:3x PC (Win2000), Control stations:2x Simatic S7-300
Implementation:invelt-elektro, s.r.o. www.invelt.cz
Date of commission:2004

Control of: PVC bench - Aliachem a.s., o.z. Fatra, Chropyně, Czech republic

Hardware:1x PC (Win2000), Control stations:1x Modicon Premium, Advantys
Implementation:XiNTECO s.r.o. www.xinteco.cz
Date of commission:2004

Heat management resurgence ČD Ostrava, Dalkia a.s., Czech republic

Hardware:3x PC (WinXP), Control stations:20x Teco
Implementation:MICROSYS, spol. s r.o. + SEMO
Date of commission:2004

Automated parking system - Melantrich Prague, Czech republic

Hardware:1x PC (WinXP), Control stations:1x Simatic S7-400
Implementation:Satec, s.r.o. www.satec.cz
Date of commission:2004

Transfer on UUK Most - mix junction - Mostecká uhelná společnost a.s., Czech republic

Hardware:1x PC (WinXP) + SQL server, Control stations: 27x RSZ, RSK - Sauter, iRSM - Martia a.s.
Implementation:Martia a.s. www.martia.cz
Date of commission:2004

ELUIII - Exchange station 800t/h, 70MW, 160 st.C - Plzeňská energetika a.s., Czech republic

Hardware:3x PC (WinXP), Control stations:Simatic S7-400
Implementation:invelt-elektro, s.r.o. www.invelt.cz
Date of commission:2004

Emission monitoring, heating plant Tábor, Czech republic

Hardware:1x PC (WinXP), Control stations:1x Datalogger DL8816
Implementation:MICROSYS, spol. s r.o. + ECM ECO Monitoring
Date of commission:2004

Exchanger control in HBZS Most - Mostecká uhelná společnost a.s., Czech republic

Hardware:2x PC (WinXP) + SQL server, Control stations:1x RSK - Sauter
Implementation:Martia a.s. www.martia.cz
Date of commission:2004

Fabrication automaton - evaluation, archiv and statistics of production data, Mubea s.r.o., Czech republic

Hardware:1x PC, Control stations:Moeller PS4
Implementation:Ing.František ŽÁK
Date of commission:2004

Excavator station - Plzeňská teplárenská a.s., Czech republic

Hardware:1x PC (Win2000), Control stations:Schneider-Electric TSX Premium
Implementation:invelt-elektro, s.r.o. www.invelt.cz
Date of commission:2004

Cover-hall of bituminous compositions, Prague, SKANSKA a.s., Czech republic

Hardware:1x PC (WinXP), 2 monitory, Control stations:1x Schneider-Electric TSX MICRO
Implementation:ESI s.r.o. www.esi.cz
Date of commission:2004

Automated parking system - Česká spořitelna Prague, Czech republic

Hardware:1x PC (WinXP), Control stations:1x Simatic S7-400
Implementation:Satec, s.r.o. www.satec.cz
Date of commission:2004

technology control - winter stadium Ústí nad Labem, Czech republic

Hardware:2x PC (WinXP), Control stations:3x Simatic S7-300
Implementation:Martia a.s. www.martia.cz
Date of commission:2004

Konverze PVS 10, Litvínov - United Energy Litvínov, Czech republic

Hardware:2x PC (WinXP) + SQL server, Control stations:9x Modicon, iRSM - Martia a.s.
Implementation:Martia a.s. www.martia.cz
Date of commission:2004

Control and monitoring system: Water power station Liptovská Mara (3000x I/O) - SE a.s. Vodné elektrárne, factory Trenčín, Slovakia

Hardware:3x PC (WinXP)
Implementation:Slovenske elektrarne a.s. www.seas.sk
Date of commission:2004

Waste water treatment plant: Monitoring and visualisation - operation, faulty states Břeclav, VaK Břeclav, a.s., Czech republic

Hardware:1x PC (WinXP), Control stations:Allen-Bradley (4x SLC5/03, 1x ML1500)
Implementation:RTP s.r.o. www.rtp.cz
Date of commission:2004

Fabrication automaton - evaluation, archiv and statistics of production data, Mubea s.r.o., Czech republic

Hardware:1x PC, Control stations:Moeller PS4
Implementation:Ing.František ŽÁK
Date of commission:2004

Extension of monitoring by 5 clients PC's, Semperflex Optimit Odry, Czech republic

Hardware:5x PC (WinXP)
Implementation:MICROSYS, spol. s r.o.
Date of commission:2004

Emission monitoring, incinerator, Valašské Meziříčí, Deza a.s., Czech republic

Hardware:1x PC (WinXP), Control stations:Datalogger, 1x AMiT Amini + 1x DINAI24
Implementation:MICROSYS, spol. s r.o., PRODEZ, a.s., ECM ECO Monitoring
Date of commission:2002, 2003, 2004

2 stations extension and visualisation by WEB on subscribers intranet, V.I.Trade s.r.o. Nitra, Slovakia

Hardware:1x PC (WinXP), Control stations:2x FX1N Mitsubishi
Implementation:DELTA plus s.r.o. www.deltaplus.sk
Date of commission:2004

Data capture system in Czech Republic power system, ČEPS, a.s., Ústřední dispečink Prague, Czech republic

Hardware:1x PC (WinXP), Control stations:8x TG809
Implementation:OSC a.s. www.osc.cz
Date of commission:2004

Distribution point monitoring - Power dispatching Eurotel, Czech republic

Hardware:1x PC (WinXP), Control stations:1x Schneider-Electric TSX Premium
Implementation:Atria s.r.o.
Date of commission:2004

Heating, ventilation, air-conditioning and sun jalousie of inteligent administrative bulding, 1.Lina a.s. Bratislava, Slovakia

Hardware:1x PC (WinXP), Control stations:1x FX1N Mitsubishi
Implementation:DELTA plus s.r.o. www.deltaplus.sk
Date of commission:2004

yeast room temperature - Pivovar Zubr, Přerov, Czech republic

Hardware:1x PC (Win2000), Control stations:1x Modicon Premium
Implementation:XiNTECO s.r.o. www.xinteco.cz
Date of commission:2004

Dispatcher SW upgrade in stokehold K13 - Doterm servis s.r.o. Meziboří, Czech republic

Hardware:1x PC (WinXP) + SQL server, Control stations:4xRSZ - Sauter
Implementation:Martia a.s. www.martia.cz
Date of commission:2004

Pressing device - evaluation, archiv and statistics of production data, CerTec s.r.o., Czech republic

Hardware:1x PC, Control stations:Simatic S7-300
Implementation:Ing.František ŽÁK
Date of commission:2004

Monitoring and control: Polyol and Isocyanat transportation, data archiv, binding to company IS - HP Pelzer Plzeň, Czech republic

Hardware:1x PC (WinXP), Control stations:Mitsubishi 2xAnA, 3xFX2N
Implementation:Atria s.r.o.
Date of commission:2004

Water chemistry processing plant + Neutralization - Plzeňská energetika a.s., Czech republic

Hardware:2x PC (WinXP), Control stations:3x Simatic S7-300
Implementation:invelt-elektro, s.r.o. www.invelt.cz
Date of commission:2004

Operation monitoring, faulty states, air-conditioning IFE Brno, Czech republic

Hardware:1x PC (WinXP), Control stations: 2xAMiT-Mest100, AMiT-AMiRiS99
Implementation:RTP s.r.o. www.rtp.cz
Date of commission:2004

Monitoring and regulation of energy consumption - Sladovny Soufflet, Kroměříž, Czech republic

Hardware:1x PC (Win2000), Control stations:1x Simatic S5 155, ET
Implementation:XiNTECO s.r.o. www.xinteco.cz
Date of commission:2004

Fabrication automaton - evaluation, archiv and statistics of production data, Mubea s.r.o., Czech republic

Hardware:1x PC, Control stations:Moeller PS4
Implementation:Ing.František ŽÁK
Date of commission:2004

Turbine TG1 50MW - Plzeňská teplárenská a.s., Czech republic

Hardware:1x PC (WinXP), Control stations:1x Simatic S5-135U, 1x S7-300
Implementation:invelt-elektro, s.r.o. www.invelt.cz
Date of commission:2004

Dispatching center of the heating plant - FN Plzeň - Plzeňská teplárenská a.s., Czech republic

Hardware:1x PC (WinXP), Control stations:Simatic S7-300
Implementation:invelt-elektro, s.r.o. www.invelt.cz
Date of commission:2004

Dispatching system of electric power consumption, Kopřivnice, DURA Automotive Systems, Czech republic

Hardware:1x PC (WinXP), Control stations:Simatic S7
Implementation:MICROSYS, spol. s r.o. + MG elektronic
Date of commission:2004

Fermentor PRAHA, MILCOM a.s., Czech republic

Hardware:1x PC (WinXP), Control stations:1x Schneider-Electric TWIDO
Implementation:ESI s.r.o. www.esi.cz
Date of commission:2004

Heating plan terminal Přerov, Dalkia ČR,a.s., heating plant Přerov, Czech republic

Hardware:2x PC (WinXP), Control stations: 2xHoneywell HPM, Mitsubishi Melsec
Implementation:OSC a.s. www.osc.cz
Date of commission:2004

Control of: Refrigeration system in malt-house - Sladovny Soufflet, Kroměříž, Czech republic

Hardware:1x PC (Win2000), Control stations:1x Teco TECOmat
Implementation:XiNTECO s.r.o. www.xinteco.cz
Date of commission:2004

Control and monitoring system, Water power station Gabčíkovo (8000xI/O) - SE a.s. Vodné elektrárne, factory Trenčín, Slovakia

Hardware:8x PC (WinXP)
Implementation:Slovenske elektrarne a.s. www.seas.sk
Date of commission:2003 - 2004

Operation monitoring, remote supervision, ČDV Oslavany, DIAMO, s.p., o.z. GEAM Dolní Rožínka, Czech republic

Hardware:1x PC (WinXP), Control stations:1x AMiT-Mest100 + DIN modules
Implementation:RTP s.r.o. www.rtp.cz
Date of commission:2004

Dispatching center of the heating plant, Dalkia a.s., ZTO Ostrava, Czech republic

Hardware:1x PC (WinXP), Control stations:8x PLC Teco, 8x IPC Octagon, heat meters
Implementation:MICROSYS, spol. s r.o. + Codea
Date of commission:2004

Monitoring and visualisation: unwoven mat production, Vertex a.s. Litomyšl, Czech republic

Hardware:2x PC (WinXP), Control stations:5x Simatic S7
Implementation:MICROSYS, spol. s r.o. + Resim
Date of commission:2004

Control and monitoring system, Water power station Kozmálovce (500xI/O) - SE a.s. Vodné elektrárne, factory Trenčín, Slovakia

Hardware:1x PC (WinXP)
Implementation:Slovenske elektrarne a.s. www.seas.sk
Date of commission:2004

Production control and heat distribution in preparation plant Komořany - Mostecká uhelná společnost a.s., Czech republic

Hardware:1x PC (WinXP) + SQL server, Control stations: 28x Landis&Gyr RWP 80 Unigir, Sauter
Implementation:Martia a.s. www.martia.cz
Date of commission:2004

Fabrication automaton - evaluation, archiv and statistics of production data, Mubea s.r.o., Czech republic

Hardware:1x PC, Control stations:Moeller PS4
Implementation:Ing.František ŽÁK
Date of commission:2004

Kneader line 5 - Gumárny Zubří, Czech republic

Hardware:1x PC (WinXP), Control stations:2x Teco NS-950
Implementation:Satec, s.r.o. www.satec.cz
Date of commission:2004

Boiler K8, 100t/h, 4,3MPa, 440 st.C, Power station Kolín a.s., Czech republic

Hardware:2x PC (WinXP), Control stations:Schneider-Electric TSX Premium
Implementation:invelt-elektro, s.r.o. www.invelt.cz
Date of commission:2004

Waste water treatment plant: Data communication - ČOV Jarcová, Babice, Kelč, Czech republic

Hardware:1x PC (WinXP), Control stations:3x Allen-Bradley Micrologix 1500
Implementation:Microsys Brno, s.r.o. www.microsysbrno.cz
Date of commission:2004

Oil levels, hydroxide level – Teepack Slavkov, Czech republic

Hardware:1x PC (WinXP), Control stations:1x Allen-Bradley PLC 5
Implementation:Microsys Brno, s.r.o. www.microsysbrno.cz
Date of commission:2004

City public transport converter station - Prague Bořislavka, Brno Kohoutovice, Czech republic

Hardware:2x PC (WinXP), Control stations:(Prague) 12x CT05, CT02, (Brno) 17x CT05, CT02
Implementation:Microsys Brno, s.r.o. www.microsysbrno.cz
Date of commission:2004

Measuring and regulation for object no. 13 - FEROX a.s. Děčín, Czech republic

Hardware:1x PC (WinXP), Control stations:1x AMiT ADiS
Implementation:LIDRA elektro
Date of commission:2004

Regulation of energy consumption in factory - FEROX a.s. Děčín, Czech republic

Hardware:1x PC (WinXP), Control stations:3x AMiT ADiS
Implementation:LIDRA elektro
Date of commission:2004

Gas stokehold 40 - FEROX a.s. Děčín, Czech republic

Hardware:1x PC (WinXP), Control stations:1x AMiT ADiS
Implementation:LIDRA elektro
Date of commission:2004

Control of power engineering and heat regulation - Kabelovna Děčín Podmokly, Czech republic

Hardware:1x PC (WinXP), Control stations:1x AMiT ADiS
Implementation:LIDRA elektro
Date of commission:2004

Fluid boiler 8t/h, Colortex Krásná Lípa, Czech republic

Hardware:1x PC (Win2000), Control stations:Modicon Premium
Implementation:SEA a.s. Příbram www.seaas.cz
Date of commission:2003

Extension of monitoring of Leadpress technology, Semperflex Optimit a.s., Czech republic

Hardware:2x PC (WinXP), Control stations:4x AMiT ART4000
Implementation:MICROSYS, spol. s r.o.
Date of commission:2003

Remote control and monitoring in TEZ Medlánky, DPMB a.s., Brno, Czech republic

Hardware:1x PC (WinXP), Control stations:Teco TC605, TC622
Implementation:MICROSYS, spol. s r.o.
Date of commission:2003

Gas stokehold, Monitoring and control (3xVS, 2xVZT), Koliba Production & Services s.r.o. Bratislava, Slovakia

Hardware:1x PC (WinXP), Control stations:6x FX1N, FX2N Mitsubishi
Implementation:DELTA plus s.r.o. www.deltaplus.sk
Date of commission:2003

Control of: transportation, composition preparation and production - Aliachem a.s., o.z. Fatra, Napajedla, Czech republic

Hardware:2x PC (Win2000), Control stations: 4x Simatic S5 (115, 100), Modicon Micro
Implementation:XiNTECO s.r.o. www.xinteco.cz
Date of commission:2003

Vehicle counting in underground garages Siemens, Prague, ELTODO a.s., Czech republic

Hardware:1x PC (WinXP)
Implementation:ESI s.r.o. www.esi.cz
Date of commission:2003

Control of production and heat distribution Důl ČSA Komořany - Mostecká uhelná společnost a.s., Czech republic

Hardware:1x PC (WinXP) + SQL server, Control stations: 32x iRSM - Martia a.s., RSZ, RSK - Sauter
Implementation:Martia a.s. www.martia.cz
Date of commission:2003

Operation monitoring, remote supervision, ČDV Běstvina, DIAMO, s.p., o.z. GEAM Dolní Rožínka, Czech republic

Hardware:1x PC (WinXP), Control stations:1x AMiT-Mest100 + DIN modules
Implementation:RTP s.r.o. www.rtp.cz
Date of commission:2003

Control and monitoring system, Water power station Tvrdošín (500xI/O) - SE a.s. Vodné elektrárne, factory Trenčín, Slovakia

Hardware:1x PC (WinXP)
Implementation:Slovenske elektrarne a.s. www.seas.sk
Date of commission:2003

Gas stokehold, Monitoring and control, Kabelovna Děčín - Podmokly a.s., Czech republic

Hardware:2x PC (WinXP), Control stations:3x RSZ - Sauter
Implementation:Martia a.s. www.martia.cz
Date of commission:2003

Gas stokehold, Monitoring and control, Hamr - United Energy, a.s., divize Energo, Czech republic

Hardware:1x PC (WinXP), Control stations:2x Modicon
Implementation:Martia a.s. www.martia.cz
Date of commission:2003

Fabrication automaton - evaluation, archiv and statistics of production data, Mubea s.r.o., Czech republic

Hardware:1x PC, Control stations:Moeller PS4
Implementation:Ing.František ŽÁK
Date of commission:2003

Control of: el. spool machine (Epsilon, Hubers) - Hanhart, Morkovice, Czech republic

Hardware:1x PC (Win2000), Control stations:1x Simatic S5 155
Implementation:XiNTECO s.r.o. www.xinteco.cz
Date of commission:2003

Monitoring of electric power in the real time, OKD, OKK a.s. Ostrava, Czech republic

Hardware:1x PC (WinXP), Control stations:2xAMiT Amini
Implementation:MICROSYS, spol. s r.o.
Date of commission:2003

Monitoring and visualisation: Bulk power substation, remote service by WEB server, error messaging by SNMP protocol - Power dispatching T-Mobile, Czech republic

Hardware:2x PC (WinXP), Control stations:2x Schneider-Electric TSX Micro, TSX Premium
Implementation:Atria s.r.o.
Date of commission:2003

Emission monitoring, Spolana Neratovice a.s., Czech republic

Hardware:1x PC (WinXP), Control stations:Datalogger
Implementation:MICROSYS, spol. s r.o. + ECM ECO Monitoring
Date of commission:2003

Gas stokehold, Monitoring and control, Hotel Zobor Nitra, Slovakia

Hardware:1x PC (Win2000), Control stations:1x FX1N Mitsubishi
Implementation:DELTA plus s.r.o. www.deltaplus.sk
Date of commission:2003

Operation monitoring, data offer to company network, ČPV Vertex Hodonice, Czech republic

Hardware:1x PC (WinXP), Control stations:4x Simatic C31x-2DP
Implementation:RTP s.r.o. www.rtp.cz
Date of commission:2003

Dispather SW upgrade in preparation plant Komořany R1/R2 - Mostecká uhelná společnost a.s., Czech republic

Hardware:2x PC (WinXP), Control stations:13x RSZ - Sauter
Implementation:Martia a.s. www.martia.cz
Date of commission:2003

Fabrication automaton - evaluation, archiv and statistics of production data, Mubea s.r.o., Czech republic

Hardware:1x PC, Control stations:Moeller PS4
Implementation:Ing.František ŽÁK
Date of commission:2003

Waste water treatment plant: Complete control, monitoring and data archive - ČOV Chodská liga (Praves Domažlice), Czech republic

Hardware:2x PC (WinXP), Control stations:2x SAIA PCD2
Implementation:Atria s.r.o.
Date of commission:2003

Cool production - West-Czech university - Plzeňská teplárenská a.s., Czech republic

Hardware:1x PC (WinXP), Control stations:Simatic S7-300
Implementation:invelt-elektro, s.r.o. www.invelt.cz
Date of commission:2003

ELUIII - Turbine and generator TG8 30MW - Plzeňská energetika, Czech republic

Hardware:1x PC (WinXP), Control stations:Simatic S7-400
Implementation:invelt-elektro, s.r.o. www.invelt.cz
Date of commission:2003

Corroborative services Pps ČEPS a.s. - Plzeňská energetika a.s., Czech republic

Hardware:2x PC (WinXP), Control stations:Simatic S7-300
Implementation:invelt-elektro, s.r.o. www.invelt.cz
Date of commission:2003

Control of: malt production (Lausman), chlazení Hupmann - Obchodní sladovny, Prostějov, Czech republic

Hardware:2x PC (Win2000), Control stations:1x Simatic S5 (135, 100)
Implementation:XiNTECO s.r.o. www.xinteco.cz
Date of commission:2003

Gas stokehold, Monitoring and control, V.I.Trade s.r.o. Nitra, Slovakia

Hardware:1x PC (Win2000), Control stations:1x FX1N Mitsubishi
Implementation:DELTA plus s.r.o. www.deltaplus.sk
Date of commission:2003

Gas stokehold, Monitoring by GSM-SMS Osek, United Energy a.s., Czech republic

Hardware:1x PC (WinNT), Control stations:1x Modicon Premium
Implementation:Sea, a.s. Příbram www.seaas.cz
Date of commission:2003

Fabrication automaton - evaluation, archiv and statistics of production data, Mubea s.r.o., Czech republic

Hardware:1x PC, Control stations:Moeller PS4
Implementation:Ing.František ŽÁK
Date of commission:2003

Turbine and generator TG 6MW - Ostrovská teplárenská a.s., Czech republic

Hardware:2x PC (Win2000), Control stations:Simatic S7-400
Implementation:invelt-elektro, s.r.o. www.invelt.cz
Date of commission:2003

Control and monitoring system, Water power station Bešeňová (400xI/O) - SE a.s. Vodné elektrárne, factory Trenčín, Slovakia

Hardware:1x PC (WinXP)
Implementation:Slovenske elektrarne a.s. www.seas.sk
Date of commission:2003

Temperatures monitoring in silo - AGROFERT Silo Rybníky, Czech republic

Hardware:1x PC (WinXP), Control stations:1x ADAM 4000
Implementation:Satec, s.r.o. www.satec.cz
Date of commission:2003

Waste water treatment plant: Operation monitoring, defect monitoring of 5 pumping stations Pasohlávky, Czech republic

Hardware:1x PC (Win2000), Control stations:1x AMiT ADiS167 + DIN modules
Implementation:RTP s.r.o. www.rtp.cz
Date of commission:2003

Control and monitoring of exchange stations by radiomodems, Z-Real Jirkov, Czech republic

Hardware:1x PC (Win2000), Control stations:8x Sea MPS
Implementation:Sea, a.s. Příbram www.seaas.cz
Date of commission:2003

Terminal of power station, ČEZ,a.s., Power station Dlouhé Stráně, Czech republic

Hardware:2x PC (WinXP), Control stations:1x AEG A500
Implementation:OSC a.s. www.osc.cz
Date of commission:2003

Terminal of power station, ČEZ,a.s., Power station Dalešice, Czech republic

Hardware:1x PC (WinXP), Control stations:1x ZAT Z300
Implementation:OSC a.s. www.osc.cz
Date of commission:2003

Monitoring and visualisation: malt-house (Seeger) - Českomoravske sladovny, Zábřeh, Czech republic

Hardware:1x PC (Win2000), Control stations:1x Simatic S5 115
Implementation:XiNTECO s.r.o. www.xinteco.cz
Date of commission:2003

Fabrication automaton - evaluation, archiv and statistics of production data, Mubea s.r.o., Czech republic

Hardware:1x PC, Control stations:Moeller PS4
Implementation:Ing.František ŽÁK
Date of commission:2003

Control of: chemical composition production - Aliachem a.s., o.z. Fatra, Chropyně, Czech republic

Hardware:1x PC (WinNT4), Control stations:1x Modicon Micro
Implementation:XiNTECO s.r.o. www.xinteco.cz
Date of commission:2003

Monitoring system of transmission stations and boiler plants, Dispatching Teplice, Czech republic

Hardware:1x PC (WinXP), Control stations:datové přenosy v síti GSM
Implementation:MICROSYS, spol. s r.o.
Date of commission:2003

Turbine TG 12MW - Actherm a.s. Chomutov, Czech republic

Hardware:2x PC (Win2000), Control stations:Simatic S7-400
Implementation:invelt-elektro, s.r.o. www.invelt.cz
Date of commission:2003

Cover-hall of bituminous compositions Hranice na Moravě, SKANSKA a.s., Czech republic

Hardware:1x PC (WinXP),2 monitory, OPC server Control stations:1x Schneider-Electric, ATRIUM, TPCX 57353
Implementation:ESI s.r.o. www.esi.cz
Date of commission:2003

Terminal of power station, ČEZ,a.s., Power station Hodonín, Czech republic

Hardware:1x PC (WinXP), Control stations:1x průmyslové PC OSC
Implementation:OSC a.s. www.osc.cz
Date of commission:2003

Control of electro-stokehold, Teplicka 22, Děčín, Czech republic

Hardware:1x PC (WinXP), Control stations:1x iRSM
Implementation:Martia a.s. www.martia.cz
Date of commission:2003

Dispatching, THMÚ Ústí nad Labem, Czech republic

Hardware:1x PC (Win2000)+ SQL server, Control stations: 80x Micropel PES, GSA, RZS, RSK - Sauter, Simatic S7, Landis&Gyr PRU 10, iRSM
Implementation:Martia a.s. www.martia.cz
Date of commission:2003

Fabrication automaton - evaluation, archiv and statistics of production data, Mubea s.r.o., Czech republic

Hardware:1x PC, Control stations:Moeller PS4
Implementation:Ing.František ŽÁK
Date of commission:2003

Cool production - Plzeňský Prazdroj a.s. - Plzeňská teplárenská a.s., Czech republic

Hardware:1x PC (WinXP), Control stations:Simatic S7-300
Implementation:invelt-elektro, s.r.o. www.invelt.cz
Date of commission:2003

Water power station Písek - river basin monitoring - JČE a.s., Czech republic

Hardware:1x PC (Win2000), Control stations:Simatic S5-115U
Implementation:invelt-elektro, s.r.o. www.invelt.cz
Date of commission:2003

Gas stokehold, Monitoring by GSM-SMS Osek, United Energy a.s., Czech republic

Hardware:1x PC (WinXP), Control stations:16x GSM modul GSA-03
Implementation:Sea, a.s. Příbram www.seaas.cz
Date of commission:2003

Control and monitoring system in TEZ, City public transport converter station Radlas, DPMB a.s., Brna, Czech republic

Hardware:1x PC (Win2000), Control stations:1x PLC Teco (1xTC600, 1xNS950)
Implementation:MICROSYS, spol. s r.o.
Date of commission:2003

Monitoring and regulation of energy consumption, TOS Varnsdorf, Czech republic

Hardware:2x PC (WinNT), Control stations:1x iRSM, Simatic S7
Implementation:MICROSYS, spol. s r.o. + Martia, a.s.
Date of commission:2003

Emission monitoring, incinerator, Katowice, Poland

Hardware:1x PC (WinXP), Control stations:Datalogger 8800
Implementation:MICROSYS, spol. s r.o. + ECM ECO Monitoring
Date of commission:2003

Vehicle counting in underground garages Carefour, Prague, ELTODO a.s., Czech republic

Hardware:1x PC (WinXP)
Implementation:ESI s.r.o. www.esi.cz
Date of commission:2003

Control of: pilot station of plastic pipes - Polymer Institute, Brno, Czech republic

Hardware:1x PC (Win2000), Control stations:1x Modicon Micro
Implementation:XiNTECO s.r.o. www.xinteco.cz
Date of commission:2003

Water power station Kružberk - Turbine 3MW, Energo-pro Czech s.r.o., Czech republic

Hardware:2x PC (Win2000), Control stations:Simatic S7-300
Implementation:invelt-elektro, s.r.o. www.invelt.cz
Date of commission:2003

Control and monitoring system: Water power station Mikšová (1500xI/O) - SE a.s. Vodné elektrárne, factory Trenčín, Slovakia

Hardware:3x PC (WinXP), Control stations:10x Octagon/ELIS (2500xI/O)
Implementation:Slovenske elektrarne a.s. www.seas.sk
Date of commission:2003

Control of: malt production (Seeger, Braumat) - Sladovny Soufflet, Kroměříž, Czech republic

Hardware:1x PC (Win2000), Control stations:1x Simatic S5 155, ET
Implementation:XiNTECO s.r.o. www.xinteco.cz
Date of commission:2003

City public transport converter station, Prague: Barrandov+Hlubočepy, Plzeň: Zátiší, Brno: Radlas+Střed, Czech republic

Hardware:1x PC (WinXP), Control stations:CT05, CT02
Implementation:Microsys Brno, s.r.o. www.microsysbrno.cz
Date of commission:2003

4 heating stations, 8 grade school Louny, Czech republic

Hardware:1x PC (WinXP), Control stations:1x AMiT ADIS
Implementation:Lidra elektro
Date of commission:2003

Pressure hose production, Monitoring and control, Semperflex a.s., Odry, Czech republic

Hardware:2x PC (Win9x,NT,SQL), Control stations:AMiT 54xART4000, 2xDOKOPO, 3x AMiT ART4000
Implementation:MICROSYS, spol. s r.o. + AMiT
Date of commission:1998, 2001, 2002

Control system: Water chemistry processing plant, Plzeňská teplárenská, a.s., Czech republic

Hardware:2x PC (Win2000 Professional), Control stations:13x PLC Schneider-Electric Nano, Micro, Premium
Implementation:invelt-elektro, s.r.o. www.invelt.cz
Date of commission:2002

Regulation of gas emitters and etaheads TEZ Pisárky, DPMB a.s., Brna, Czech republic

Hardware:1x PC (Win2000), Control stations:Etahlavice + plynové zářiče
Implementation:MICROSYS, spol. s r.o.
Date of commission:2002

Monitoring and control: Chicken hatch, Xaverov, a.s. branch Habry, Czech republic

Hardware:1x PC (Win98, 4xCOM), Control stations: 2xAMiT, 10xOmron
Implementation:Antonín Hradil
Date of commission:2002

Emission monitoring, incinerator, Ústí nad Labem, Spolchemie, Czech republic

Hardware:1x PC (Win98), Control stations:Datalogger 8816
Implementation:MICROSYS, spol. s r.o. + ECM ECO Monitoring
Date of commission:2002

Remote control in TEZ Medlánky, I.phase, DPMB a.s., Brna, Czech republic

Hardware:1x PC (Win2000), Control stations:6x PLC Teco (5x TC600, 1x NS950)
Implementation:MICROSYS, spol. s r.o.
Date of commission:2002

Turbine TG2, Power station NH, a.s. Ostrava, Czech republic

Hardware:1x PC (Win2000)+TouchScreen, Control stations:SAIA PCD4
Implementation:NH, a.s. Ostrava, Automatizace-455
Date of commission:2002

Exchange station, elementary school Jirkov, Monitoring and control, Czech republic

Hardware:1x PC (Win98), Control stations:1x Sea MPS
Implementation:Sea, a.s. Příbram www.seaas.cz
Date of commission:2002

Dust exhausting of arc furnace No.3, Siderurgica, Hunedoara, Romania

Hardware:1x PC (Win98), Control stations:1x Simatic S7-300
Implementation:Microcomp s.r.o. www.microcomp.sro.cz
Date of commission:2002

Cooling engine room, Monitoring and control, Interpharma Prague, Czech republic

Hardware:1x PC (Win98), Control stations:1xModicon Premium
Implementation:Sea, a.s. Příbram www.seaas.cz
Date of commission:2002

Measuring system of pumps testing, Sigma Group a.s., Lutín, Czech republic

Hardware:1x PC (Win9x), Control stations:Měřicí ústředna HP34970
Implementation:MICROSYS, spol. s r.o. + AMES s.r.o.
Date of commission:2002

Control system: Turbine 70 MW, Plzeňská teplárenská, a.s., Czech republic

Hardware:2x PC (Win2000 Pro), Control stations:Simatic S5-135U
Implementation:invelt-elektro, s.r.o. www.invelt.cz
Date of commission:2002

Register program of boat weigh - HOLCIM, Pískovna Dobříň, Czech republic

Hardware:1x PC (Win98), Control stations:1x Vaha Boekels
Implementation:Satec, s.r.o. www.satec.cz
Date of commission:2002

Monitoring and regulation of energy consumption, UNION Lesní Brána, Teplice-Dubí, Czech republic

Hardware:1x PC (WinNT), Control stations:iRSM, Simatic S7
Implementation:MICROSYS, spol. s r.o. + Martia a.s.
Date of commission:2002

Control system: Turbine 12 MW, ACTHERM, s.r.o. factory Chomutov, Czech republic

Hardware:2x PC (Win2000 Pro), Control stations:Simatic S7-400
Implementation:invelt-elektro, s.r.o. www.invelt.cz
Date of commission:2002

Central power dispatching center, Sokolov, RSM CHEMACRYL, a.s., Czech republic

Hardware:12x PC (WinNT, Win9x), Control stations:Průmyslové PC + PLC Modicon
Implementation:MICROSYS, spol. s r.o.
Date of commission:2002

Exchange stations, Monitoring and control, DPMB a.s., Brno, Czech republic

Hardware:2x PC (Win2000), Control stations:Teco TR300, TC600
Implementation:MICROSYS, spol. s r.o. + Sting Energo
Date of commission:1999 - 2001

Electricity consumption and production dispatching system - ZSNP, a.s., Závod Energetik, Slovakia

Hardware:1x PC (WinXP), Control stations:1x ADAM 6051
Implementation:ZSNP, a.s.
Date of commission:2001

Silos temperature monitoring - ZENZA Rakšice, Czech republic

Hardware:1x PC (Win2000), Control stations:1x ADAM 5000
Implementation:Satec, s.r.o. www.satec.cz
Date of commission:2001

Control system: shelf interpolator, Karosa Vysoké Mýto, Czech republic

Hardware:1x PC (Win9x), Control stations:Mitsubishi
Implementation:MICROSYS, spol. s r.o.
Date of commission:2001

Monitoring and control: VVTL gas control, Bylany, SČP a.s., Czech republic

Hardware:1x PC (WinNT), Control stations:2x Sea MPS
Implementation:Sea, a.s. Příbram www.seaas.cz
Date of commission:2001

Diary Klatovy, Czech republic

Hardware:1x PC (Win9x), Control stations:AMiT ART 400
Implementation:RTP, s.r.o.
Date of commission:2001

Hydrotalcit production, Chemical processing plant, Dolní Rožínka, Czech republic

Hardware:1x PC (Win9x), Control stations:AMiT ADiS + DIOCAN
Implementation:RTP, s.r.o.
Date of commission:2001

HV and LV circuit breakers, Monitoring and control, MAFRA Prague, Czech republic

Hardware:1x PC (Win9x), Control stations:ABB SCU REF542
Implementation:MICROSYS, spol. s r.o.
Date of commission:2001

Monitoring system of vibrations and bearings on digger and DPD, SD Bílina, Czech republic

Hardware:1x PC (Win9x), Control stations:8x ZAT, Simatic
Implementation:CMMS s.r.o. www.cmms.cz
Date of commission:1997 - 2001

Diagnostic system of vibrations and bearings on heating plant 700, Chemopetrol, Litvínov, Czech republic

Hardware:1x PC (Win98), Control stations:Honeywell + MPMCM2
Implementation:CMMS s.r.o. www.cmms.cz
Date of commission:2000 - 2001

Register system of weigh - Bajkalskie mineraly, Russia

Hardware:1x PC (WinNT), Control stations:1x Simatic S7-200
Implementation:Satec, s.r.o. www.satec.cz
Date of commission:2001

Weigh to special oven - Ferex ŽSO, Liberec, Czech republic

Hardware:1x PC (Win2000), Control stations:1x Simatic S7-300
Implementation:Satec, s.r.o. www.satec.cz
Date of commission:2001

Monitoring of cooling engine room, Unilever s.r.o. Nelahozeves, Czech republic

Hardware:1x PC (WinNT), Control stations:1x Modicon Premium
Implementation:Sea, a.s. Příbram www.seaas.cz
Date of commission:2001

Diagnostic system of vibrations, Česká rafinérská a.s., Kralupy n/Vltavou, Czech republic

Hardware:2x PC (Win98), Control stations:SKF M800 + Prism/Microlog
Implementation:CMMS s.r.o. www.cmms.cz
Date of commission:2001

Control of exchange stations, OEZ Letohrad s.r.o., Czech republic

Hardware:1x PC (Win9x), Control stations:AMiT AMiRiS99, AMAP99, APT130
Implementation:Regprofi s.r.o., Hradec Králové, AMiT s.r.o.
Date of commission:2001

Heating and air conditioning of facilities, Comfort association, Plzeň, Czech republic

Hardware:1x PC (Win9x), Control stations:AMiT 3xAMiRiS, 3xAMiRiS99, AMAP98
Implementation:Comfort sdružení Plzeň, AMiT s.r.o.
Date of commission:2001

Measuring and regulation of quarter-hour consumption, FEROX a.s., Děčín, Czech republic

Hardware:1x PC (Win9x), Control stations:AMiT 3xADiS, AMiRiS
Implementation:ERVIS s.r.o., Ústí n. L.
Date of commission:2001

Emission monitoring, heating plant Z.E.C. Inowroclaw, Poland

Hardware:1x PC (WinNT), Control stations:Datalogger 8816
Implementation:MICROSYS, spol. s r.o. + ECM ECO Monitoring
Date of commission:2001

Control system: Turbine 6,8 MW, CINERGETIKA Ústí nad Labem, a.s., Czech republic

Hardware:1x PC (Win2000), Control stations:Simatic S5-135U
Implementation:invelt-elektro, s.r.o. www.invelt.cz
Date of commission:2000

Regulation of steam boiler plant BOZP, Meat processing Polička, Czech republic

Hardware:1x PC (Win9x), Control stations:AMiT ADiS, APT130
Implementation:MaRMONT s.r.o., Chotěboř
Date of commission:2000

Waste water treatment plant, Benátecká Vrutice, Czech republic

Hardware:1x PC (Win9x), Control stations:AMiT 3xADiS, AMiRiS
Implementation:UNITECH Štěfan Macejka
Date of commission:2000

Control system: Water chemistry processing plant, Plzeňská teplárenská, a.s., Czech republic

Hardware:1x PC (Win2000), Control stations:2x Simatic S7-300
Implementation:invelt-elektro, s.r.o. www.invelt.cz
Date of commission:2000

Processing line control of rubber pre-mixtures, Adds TYRE Comp., Adis Abeba, Ethiopie, Ethiopia

Hardware:1x PC (Win98), Control stations:2x Simatic S7-400
Implementation:A.S.P.R. s.r.o.
Date of commission:2000

Measuring of purity of expanded CO2, Emission monitoring H2S - Chemopetrol, a.s., Czech republic

Hardware:1x PC (WinNT), Control stations:Datalogger 8816, ADAM 4017
Implementation:MICROSYS, spol. s r.o. + ECM ECO Monitoring
Date of commission:2000

Control system: Water chemistry processing plant, Plzeňská energetika, a.s., Czech republic

Hardware:1x PC (Win2000), Control stations:2x Simatic S7-300
Implementation:invelt-elektro, s.r.o. www.invelt.cz
Date of commission:2000

Turbine and generator TG 8MW, Setuza a.s. Ústí/L, a.s., Czech republic

Hardware:1x PC (Win2000), Control stations:Simatic S5-135U
Implementation:invelt-elektro, s.r.o. www.invelt.cz
Date of commission:2000

Grading-up of processing line of steel products, ZETOR a.s. Brno, Czech republic

Hardware:1x PC (Win9x), Control stations:SAIA
Implementation:MICROSYS, spol. s r.o. + Elektroteplo Kolín
Date of commission:2000

Control and evaluation of material deformation tests, Polymer Institute Brno, Czech republic

Hardware:1x PC (Win98), Control stations:AMAP99, APT130
Implementation:XiNTECO Kroměříž
Date of commission:2000

Control of switching station 110/22kV, Energoaqua a.s., Rožnov pod Radhoštem, Czech republic

Hardware:1x PC (Win98), Control stations:3x Simatic S7-300
Implementation:A.S.P.R. s.r.o.
Date of commission:2000

Diagnostic system of vibrations and bearings in Energotrans, Energotrans, Prague, Czech republic

Hardware:2x PC (Win98), Control stations:SKF systém Multilog/Prism
Implementation:CMMS s.r.o. www.cmms.cz
Date of commission:2000

Monitoring of air consumption, PLEAS Havlíčkův Brod, Czech republic

Hardware:1x PC (Win9x), Control stations:NEWPORT
Implementation:MICROSYS, spol. s r.o.
Date of commission:2000

Diagnostic system of bearings in paintshop, Škoda auto, a.s. Mladá Boleslav, Czech republic

Hardware:1x PC (Win98), Control stations:SKF systém Multilog/Prism
Implementation:CMMS s.r.o. www.cmms.cz
Date of commission:1998 - 2000

Diagnostic system of vibrations and bearings, ČEZ EPO Trutnov, Czech republic

Hardware:1x PC (Win98), Control stations:SKF systém Multilog/Prism
Implementation:CMMS s.r.o. www.cmms.cz
Date of commission:2000

Dispatching system of production and transport dispatching center, OKD a.s., Důl ČSM o.z., Czech republic

Hardware:6x PC (Win98), Control stations:1x MTA 21.30, 1xPRES
Implementation:MTA Ostrava s.r.o.
Date of commission:2000

Control and regulation of quarter-hour consumption, VPO Protivanov, Czech republic

Hardware:1x PC (Win9x), Control stations:AMiT AMiRiS99
Implementation:SKS s.r.o.
Date of commission:2000

Modernization of gunite production, Lime-kiln Čebín, Czech republic

Hardware:1x PC (WinNT), Control stations:Simatic S5
Implementation:Microsys Brno, s.r.o. www.microsysbrno.cz
Date of commission:2000

Air-transport of flour, Baker Prostějov, Czech republic

Hardware:1x PC (Win98)
Implementation:MICROCOMP Milevsko
Date of commission:2000

Checking system and control of Water power station Vranov n/Dyjí TG1 Jihomoravská energetika, Czech republic

Hardware:1x PC (WinNT), Control stations:SAIA PCD4
Implementation:BOHEMIA INSTRUMENTS
Date of commission:2000

Diagnostic monitoring system of turbine generator unit 200 MW, Nuclear power station Mochovce, Slovakia

Hardware:1x PC (WinNT), Control stations:3x SAIA PCD4, 12xDIAMO L
Implementation:BOHEMIA INSTRUMENTS
Date of commission:2000

Dispatching center of power in housing enterprise Štúrovo (15MW), Slovakia

Hardware:1x PC (Win9x), Control stations:14x Simatic S7-216
Implementation:Delta Plus, Siemens Bratislava
Date of commission:2000
© MICROSYS, spol. s r. o.Tavičská 845/21 703 00 Ostrava-Vítkovice